REMOTE OPERATION (CONT'D)
SLEEP MODE
After 8 hours of no signal between the handset and the
receiver valve runs to pilot and the
Sleep Mode icon is
displayed.
TURN OFF GAS TO APPLIANCE
Access the gas control.
Turn the main valve knob clockwise
to the PILOT
position. Push in knob; turn and release. Continue turning
to the OFF full clockwise
position.
Replace appliance accessibility cover (if applicable).
MANUAL VALVE OPERATION
1. STOP! Read the safety information included before
proceeding.
2. Turn main valve knob to the OFF full clockwise
position.
3. Turn the MANUAL knob to the full clockwise
position.
4. Wait five (5) minutes to clear out any gas. Verify that
no gas is in the area around the appliance, including
near the floor.
If you detect gas STOP! Follow
Warnings (see pg. 16) under “What to do if you
smell gas”.
If no gas is present, proceed to step 5.
5. Turn main valve knob slightly counterclockwise
towards the IGN position unitl it stops, then
press down and continue turning counterclockwise
to the pilot position. Continue to hold down
knob for 10 seconds after pilot burner has been lit. If
pilot does light, steps 1 and 2 may be repeated.
NOTE:
If the pilot does not stay lit after several tries,
turn main valve knob to the PILOT position. Push in
knob; turn and release. Continue turning to the OFF
full clockwise
position and proceed to step 7.
6. Upon lighting, release knob and turn main valve knob
fully counterclockwise
to ON position.
7. If the appliance will not operate, follow the
instructions “Turn Off Gas to Appliance”.
MANUAL FLAME HEIGHT OPERATION
The motorized valve is equipped with a slip clutch allowing
manual adjustment of the main burner by turning the
manual knob. When turning the manual knob, do not force.
STANDBY PROCEDURE
Turn main valve knob clockwise
to Pilot position,
allowing only pilot gas to flow.