Tank Level and Pre-treatment Lockout Wiring
The Whole House RO system is equipped with two switch closure circuits that control the
RO system ON/OFF function. This is a "no voltage" switch closure circuit (dry contact).
Tank Level Input
There is a switch closure circuit used to turn some RO systems on and off when an at-
mospheric tank float is installed. The float switch wires as follows:
The wires above show color coatings. However, the colors do not matter. There is no volt-
age to these wires. They just need to be wired in a loop that can open or close when nec-
essary.
BE SURE
to use the blue and black wires only on the float.
IMPORTANT! Do not apply voltage to the tank level input circuit. This will damage
the RO system.
27