Anti-Scalant Filling and Settings
If anti-scalant is used in lieu of a water softener to control hardness, the dose and mix is
determined using the feed water analysis, the chemical pump specifications and the RO
system operating parameters. The table below can be used in 90% of the applications.
However, in some rare cases, the Penguin Water representative will have specific guide-
lines. If this is the case, the representative will make it known. Use the following proce-
dure when filling the tank:
1.
Fill the tank with 5 gallons of clean water (preferably RO water). Add specified oz of
the anti-scalant solution for each gallon of water to the tank using the table provided.
2.
Cut the smooth portion of the injection check valve off, up to the male threads. This
is to ensure the outlet does not bottom out and restrict flow of the solution.
3.
Install the injection check valve in the chemical injection port on the RO system after
the sediment filter. This should be labeled with a pipe plug installed.
4.
Plug the chemical injection pump into the chemical injection pump female cord la-
beled "Dosing Pump" on the RO system. This cord is energized when the RO system
is operating.
5.
Make sure the toggle switch on the injection pump is in the "ON" position.
29
Summary of Contents for PWCRO
Page 1: ...Penguin Water Whole House RO 224 PWCRO XXXX ...
Page 11: ...20 UV Controller Monitors the UV light performance and bulb life 11 ...
Page 30: ...30 ...
Page 41: ...Membrane Flow Overview 41 ...
Page 42: ...42 ...
Page 43: ...43 ...
Page 44: ...44 ...
Page 47: ...System Flow Diagram 47 ...
Page 48: ...48 ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 51: ...Typical System Layout 51 ...
Page 56: ...Electrical Schematic 56 ...