64
Troubleshooting and maintenance
Emotron AB 01-3991-11r2
Load monitor error description
Table 29
Display
Error
Cause
Corrective Action
Trip for underload
Minimum load alarm level
(underload) has been reached.
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
Pre-alarm under-
load
Actual load reaches minimum
pre-alarm margin.
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
Trip for overload
Maximum load alarm level (over-
load) has been reached.
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
Pre-alarm overload
Actual load reaches maximum
pre-alarm margin.
1. Check the load condition
of the machine.
2. Check the monitor setting
in [411] to [429].
ut
Put
Ot