Page 8
UPA-200
UPA-200 Rear Panel
1
2
R
CH 2
1
0
L
CH 1
115V
|
POWER
|
230V
INPUT OUTPUT
- + - +
5V - 12V DC 12V - DC
STATUS LEDS
OFF ON
3
4
5 6
7
8
1. Status LED Switch
Enables and disables the front panel Channel Status LEDs.
2. RCA (unbalanced) Input
Unbalanced audio input (gold plated RCA jack; right channel shown).
3. Line Voltage Indicator
The UPA-200 automatically detects 115 VAC or 230 VAC line voltage. These indicators
show which line voltage is in use.
4. AC Power Switch
Switches the mains AC power to the UPA-200 On and Off. When this switch is off, no
controls operate (the UPA-200 cannot be turned On from the front panel).
5. and 6. Trigger Input and Trigger Output
The UPA-200 is switched On (from Standby) when a trigger signal is presented at the
Trigger Input; the UPA-200 returns to Standby when the trigger signal is removed. When the
UPA-200 is on, a 12 VDC signal is sent from the Trigger Output to control other devices.
7. Speaker Output
Full-sized five-way binding posts; accept 4 Ohm or 8 Ohm speakers (+ red; - black).
8. IEC Power Cord Receptacle
Accepts a standard removable IEC AC power cable. If you replace this, only use power
cables of sufficient current capacity.