background image

Page 17

UPA-200

EMOTIVA SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL 

DAMAGES ARISING FROM OR RELATED TO ANY DEFECTS IN OR DAMAGES TO 

ITS PRODUCTS.  SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION 

OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR 

EXCLUSION MAY NOT APPLY TO YOU.

How do you get service?

   In order to make a claim under the warranty, you must:

1. 

Call a customer service representative (“CSR”) of Emotiva at 1-877-EMO-TECH  

 

 

(1-877-366-8324).  Provide the CSR with a description of your problem and the

 

 

serial number of the product for which the warranty claim is being made.  

2. 

The CSR will provide you with a returned material authorization number (“RMA”).  

3. 

Ship the product to Emotiva at the following address, with the RMA written in large,

 

 

bold numbers on the outside of the box, and with the letters “RMA” written before the

 

 

number.  Parcels arriving without an RMA number on the outside of the box will be

 

 refused. 

 

Emotiva Audio Corporation

 

 

Attn: Repair Department

 

 

135 Southeast Parkway Court

 

 

Franklin, TN 37064

How does state law apply?

  This warranty gives you specific legal rights, and you may 

also have other rights which vary from state to state.  

Summary of Contents for upa-200

Page 1: ...UPA 200 Stereo Power Amplifier User Manual UPA 200...

Page 2: ......

Page 3: ...SERVICE TO QUALIFIED SERVICE PERSONNEL Do not install the UPA 200 near or above any heat sources such as radiators heating vents or any other apparatus that produces heat Do not block any ventilation...

Page 4: ...vice for your UPA 200 by qualified service personnel if any of the following occur 1 The power supply cord or the plug has been damaged 2 Objects or liquid have fallen or spilled into the vents 3 The...

Page 5: ...Manual 4 Features 5 Unpacking 6 UPA 200 Front Panel 7 UPA 200 Rear Panel 8 Quick Start 9 Connections 10 Configuration and Operation 11 Care and Maintenance 12 Specifications 13 Troubleshooting 15 Emot...

Page 6: ...Page 2 UPA 200...

Page 7: ...cient speakers to satisfying sound levels and sounds great doing it Inside the UPA 200 boasts the advanced engineering high quality components heavy duty toroidal transformer power supply proven Class...

Page 8: ...rough the entire manual we kept things as short and direct as possible Even if you re an expert user you will probably find some interesting information and useful suggestions If you re really in a hu...

Page 9: ...d toroidal transformer provides plenty of real power continuous both channels driven for demanding program material and has plenty of reserves to deliver signal peaks without any sense of strain Total...

Page 10: ...ton and remove all wrappings and shipping material It is important to save the box and all packing materials in case your power amp ever needs to be moved or shipped back to the factory for service Pl...

Page 11: ...Channel Status LED Illuminates blue for normal operation or red to indicate a fault may be disabled by rear panel Status LED switch 2 Standby Button Press to switch amplifier On press again to return...

Page 12: ...s AC power to the UPA 200 On and Off When this switch is off no controls operate the UPA 200 cannot be turned On from the front panel 5 and 6 Trigger Input and Trigger Output The UPA 200 is switched O...

Page 13: ...ource a pre pro a preamp a DAC with an output level control we make some nice ones or even an iPod as long as it has a variable output level Connect your UPA 200 to a pair of speakers 4 Ohm or 8 Ohm u...

Page 14: ...t 10 gauge wire for the other If you use stranded cables use care to avoid short circuits from stray strands touching Emotiva offers very high quality pre made speaker cables at reasonable prices you...

Page 15: ...ber Pressing this button once will switch the UPA 200 On and the LED will turn blue pressing it again will return the UPA 200 to Standby mode Trigger Mode When a trigger cable is connected to the Trig...

Page 16: ...uld be cleaned gently with a soft rag If something sticky gets on the front panel or case of the UPA 200 it should be cleaned with a mild cleaning solution applied to a soft rag followed by wiping wit...

Page 17: ...ommended Load Impedance 4 ohms which equals one 4 ohm load or two paralleled 8 ohm loads per channel Frequency Response 5 Hz to 80 kHz 0 2 dB THD N 0 03 Signal to Noise Ratio 8 Ohm load 92 dB at 1 wat...

Page 18: ...or normal operation or red to indicate a fault may be disabled by rear panel Status LED switch Rear Panel Controls AC Power switch rocker switch switches AC mains power Status LEDs switch small slide...

Page 19: ...is heard from one or more channel s the Standby button is lit blue the Channel Status LEDs are all lit blue Reason The UPA 200 is not indicating a Fault condition Check your source Check your speakers...

Page 20: ...m if it is not made within the Term and if it is not made in strict compliance with the requirements of the How do you get service section What will Emotiva do Emotiva will at its option either i repa...

Page 21: ...CSR with a description of your problem and the serial number of the product for which the warranty claim is being made 2 The CSR will provide you with a returned material authorization number RMA 3 Sh...

Page 22: ...e speakers connected to it Emotiva Audio offers high quality speaker cables and audio interconnects that feature solid engineering premium build quality excellent performance and reasonable cost You w...

Page 23: ...is accurate to the best of our knowledge at the time of publication In keeping with our policy of ongoing product improvement we reserve the right to make changes to the design and features of our pr...

Page 24: ......

Page 25: ......

Reviews: