background image

5

The connected heating appliance should be at a sufficient distance 

from the socket to prevent the devices from influencing each other.

Otherwise, the socket may activate the appliance when not needed.

Putting the Device into Operation

Plug the socket into a 230 V/50 Hz socket; the screen will activate.

Plug the appliance into the thermostatic socket.

Activating Thermo-Switch Socket (Thermostat) Mode 

Long-press the TIME and MODE buttons at the same time to access 

settings.

Repeatedly press the + and – buttons to select the mode marked 

as „tHE“ 

.

Confirm by pressing the TIME button and continue with further 

settings.

The settings below are only available when in thermostat mode!
Heating or Cooling Mode

Long-press the TIME and MODE buttons at the same time and then 

press the TIME button 1×.

Use the + and – buttons to choose between heating 

 or 

cooling 

   mode.

Confirm by pressing TIME; this will open:

Temperature Differential Setting

Use the + and – buttons to set a value of 0.2 °C to 2 °C, with 0.1 °C 

resolution.

Confirm by pressing TIME; this will open:

Room Temperature Calibration

Use the + and – buttons to set a value of -3 °C to +3 °C, with 0.5  °C 

resolution.

Wait 30 seconds or press MODE to save the setting and return to 

the main screen.

Explanation of functions:

Temperature Differential Setting

The temperature differential (hysteresis) is the difference in tempe-

rature required for switching the system on and off.

If, for example, you set the temperature in heating mode to 20 °C 

and differential to 0.2 °C, the thermostat activates heating as soon 

as room temperature drops to 19.8 °C and switches heating off when 

temperature reaches 20.2 °C.

Room Temperature Calibration

The temperature sensor in the thermostat is calibrated from producti-

on, but additional calibration can be done to optimise the thermostat 

further, for instance by comparing the measured room temperature 

with a reference thermometer.

Setting Day and Time

Press the TIME button; the day number will begin flashing.

Use the + and – buttons to set the current day and press TIME to 

confirm.

The month number will start flashing. Use the + and – buttons to set 

the current month and press TIME to confirm.

Summary of Contents for P5660FR

Page 1: ...GB Thermostatic and Timer Socket CZ Termostatick a asov sp nan z suvka SK Termostatick a asovo sp nan z suvka PL Gniazdo termostatyczne z w cznikiem czasowym 2106000100_31 P5660FR_00_01 75 148 mm www...

Page 2: ...2 1 5 3 8 9 4 2 7 10 1 6...

Page 3: ...3 3 2 4 3 2 1 4 5 6 7 2 1 3 4 5 6...

Page 4: ...Elements See Fig 1 1 socket for connecting an appliance 2 BOOST button 3 button 4 TIME button 5 screen 6 temperature sensor 7 PROG button 8 button 9 RESET 10 MODE button On Screen Indicators in Therm...

Page 5: ...2 C with 0 1 C resolution Confirm by pressing TIME this will open Room Temperature Calibration Use the and buttons to set a value of 3 C to 3 C with 0 5 C resolution Wait 30 seconds or press MODE to...

Page 6: ...o not suit your needs you can adjust their timing and temperatures The day can be divided into a maximum of 6 time periods 6 tem perature changes 1 Press the PROG button the day number will begin flas...

Page 7: ...ature and wait 5 seconds for the setting to automatically save P programme number will disappear from the screen AUTO will remain The manually set temperature will be maintained until the pro grammed...

Page 8: ...matically save the setting and return to the main screen Table of Factory Preset Times Activation time ON Deactivation time OFF Monday Sunday Monday Friday Mon Tue Wed Thu Fri Saturday Sunday Sat Sun...

Page 9: ...OST button repeatedly until the time setting reaches 9 hours the next press then deactivates the BOOST function Note The BOOST function cannot be used in manual mode ON Manual Mode ON Press the MODE b...

Page 10: ...ts or immerse the device in water The device is not intended for use by children or persons whose physical sensory or mental disability or lack of experience and expertise prevents safe use unless the...

Page 11: ...vlo te novou 3 Dbejte na dodr en spr vn polarity stranou nahoru 4 Vra te zp t kryt a za roubujte ho A PROVOZ V RE IMU TEPELN SP NAN Z SUVKY TERMOSTATU Um st n z suvky Zvolte m sto nejl pe na vnit n z...

Page 12: ...dos hne 20 2 C Kalibrace pokojov teploty Teplotn senzor v termostatu byl ji kalibrov n p i v rob ale pro optimalizaci je mo n prov st kalibraci teploty v m stnosti dle nap referen n ho teplom ru Nast...

Page 13: ...hodnota asu a bude zobrazeno P2 2 teplotn zm na v r mci dne 7 Nastavte tla tky a as od kdy za ne platit 2 teplotn zm na potvr te tla tkem TIME 8 Za ne blikat hodnota teploty nastavte tla tky a po ado...

Page 14: ...aj c nastaven as a teplota s pokojovou teplotou a hodinami Po uplynut t to doby dojde automaticky k n vratu do p ede l ho teplotn ho re imu a p vodn nastaven teplot Pro p ed asn ukon en funkce BOOST z...

Page 15: ...Za ne blikat hodnota asu a bude zobrazeno P2 ON zapnut 2 programu 8 Stejn m zp sobem nastavte dal asov programy Pro ukon en nastaven po kejte 1 minutu nebo stiskn te tla tko MODE B hem programu zapnut...

Page 16: ...ve venkovn ch prostorech je zak z no Nep et ujte p stroj aby nedo lo k jeho po kozen P stroj mus b t p ipojen a pou v n jen v elektrick s ti 230 V AC 50 Hz kter je opat ena ochrann m kontaktem podle p...

Page 17: ...e rebr ky infrapanely klimatiz cia Technick pecifik cia Nap janie 230 V 50 Hz 16 A max IP krytie IP30 Pracovn teplota 0 C a 55 C Interval pre nastavenie asu 1 min ta Sp nan z a max 230 V AC 3 680 W 16...

Page 18: ...idlom TIME a pokra ujte v al om nastaven Nasleduj ce nastavenia s dostupn iba v re ime termostatu Re im vykurovania alebo chladenia Stla te s asne dlho tla idlo TIME a MODE a potom 1 tla idlo TIME Opa...

Page 19: ...17 00 21 C P6 22 00 15 C Time Temperature Saturday Sunday P1 7 30 20 C P2 9 30 20 C Sat Sun P3 11 30 20 C P4 13 30 20 C P5 16 30 21 C P6 22 30 15 C Nastavenie programov automatick re im Pokia v m tov...

Page 20: ...pleji v avo bude zobrazen AUTO a P programu nastavte tla idlami a nov hodnotu teploty po kajte 5 sek nd d jde k automatick mu ulo eniu Na displeji zmizne P programu a bude zobrazen AUTO Manu lne nasta...

Page 21: ...e MODE Tabu ka tov rnE prednastaven ch asov as zapnu tia ON as vypnu tia OFF Pondelok nede a Pondelok piatok Po t St t Pia Sobota nede a So Ne P1 6 00 8 00 P2 12 00 14 00 P3 17 00 22 00 Nastavenie pro...

Page 22: ...mo no pou i v manu lnom re ime ON Manu lny re im ON Opakovane stla te tla idlo MODE na displeji v avo bude zobrazen ON a ikona prev dzky alebo Z suvka bude st le v prev dzke Nastaven re im bude platn...

Page 23: ...na predajcu zariadenia Pri isten pr stroja a LCD displeja pou vajte len such m kk handri ku Nepou vajte iadne istiace prostriedky a nepon rajte pr stroj do vody Pr stroj nesm obsluhova deti a osoby k...

Page 24: ...a Informacje wy wietlane na wy wietlaczu w trybie timera patrz rys 3 1 tryb czasowy 2 ikona pracy 3 numer dnia 4 czas 5 numer programu 6 roz adowana bateria rezerwuj ca Wymiana baterii rezerwuj cej Ba...

Page 25: ...kolejno przyciski i ustawiamy warto 3 C do 3 C rozdzielczo 0 5 C Aby zapisa i wr ci w programie czekamy 30 sekund albo nacis kamy MODE Wy wietlanie funkcji Histereza ustawionej temperatury Rozrzut hi...

Page 26: ...ury Ca y dzie mo na podzieli na maks 6 odcink w czasowych 6 zmian temperatury 1 Naciskamy przycisk PROG zaczyna miga numer dnia 1 do 7 poniedzia ek do niedzieli 2 Przyciskami i wybieramy wymagane dni...

Page 27: ...wania temperatury na wy wietlaczu z lewej strony zostanie wy wietlone AUTO i P nr programu przyciskami i ustawiamy now warto temperatury czekamy 5 sekund a dojdzie do automatycznego zapisania Na wy wi...

Page 28: ...em TIME Zaczyna miga minuta przyciskami i ustawiamy aktualn minut i potwierdzamy przyciskiem TIME W celu automatycznego zapisania i powrotu czekamy 30 sekund albo naciskam MODE Tabelka fabrycznie zapr...

Page 29: ...wionego czasu dojdzie do automatycznego prze c zenia do poprzedniego trybu Aby wcze niej zako czy funkcj BOOST wybieramy przyciskiem MODE inny tryb albo kolejno naciskamy przycisk BOOST do warto ci 9...

Page 30: ...zerwany przew d ochronny doprowadzony do urz dzenia w przypadku przerwania prze wodu ochronnego powstaje zagro enie dla ycia Zalecana temperatura pracy wynosi od 0 C do 55 C Trzeba wykluczy prac tego...

Page 31: ...31 cje mog yby przesi ka do w d podziemnych przedostawa si do a cucha pokarmowego i szkodzi zdrowiu i samopoczuciu ludzi...

Reviews: