unit of precipitation: mm/inch
radio signal range: to 100 m in open area
number of sensors which can be connected: max. 3 (temperature/humidity/wind sensor), max. 1
(precipitation sensor)
wireless sensor: transmission frequency 433 MHz, 10 mW e.r.p. max.
station power supply: 3× 1.5 V AAA batteries (not included)
adapter AC 230 V/DC 5 V, 300 mA (included)
temperature/humidity/wind sensor power supply: 4× 1.5 V AA (not included)
precipitation sensor power supply: 2× 1.5 V AA (not included)
station dimensions and weight: 17 × 192 × 127 mm, 364 g
temperature/humidity/wind sensor dimensions and weight: 275 × 135 × 310 mm, 377 g (without
batteries)
precipitation sensor dimensions and weight: 100 × 106 × 166 mm, 220 g (without batteries)
Getting Started/Installation
1. Plug the power adapter into the station, then insert batteries first into the weather station (3× 1.5 V
AAA) and then into: wireless temperature/humidity/wind sensor (4× 1.5 V AAA) and wireless
precipitation sensor. The battery compartment of the precipitation sensor is protected by screws;
use a suitable screwdriver.
2. When inserting the batteries make sure the polarity is correct to avoid damaging the weather
station or sensors. Only use alkaline batteries of the same type; do not use rechargeable batteries.
3. Place all the units next to each other. The weather station will automatically detect the signal from
sensors within 3 minutes. If signal from sensors is not detected, long-press the
button on the
weather station to repeat the search and press the TX button on the sensor.
4. To ensure correct measurement, the temperature/humidity/wind sensor and precipitation sensor
must be placed above the ground surface (at least 1.5 m) onto a horizontal surface and outside of
buildings and structures. Both sensors must be firmly screwed on to prevent their damaging. First,
screw the mounting plate onto a level surface, then mount the mounting rod into it. Screw the
temperature/humidity/wind sensor onto the rod. Wind must flow freely around the wind sensor
from all sides. Check that the wind direction indicator and paddles for measuring wind speed can
rotate freely. The north arrow (N) on the built-in compass must point to the real north. Otherwise,
wind direction will always be displayed incorrectly. When choosing a suitable place for mounting
the sensor, check before installation that the main station is within range of the sensors. The range
of the sensors may decrease substantially in areas with large number of obstacles.
5. Do not place the sensors onto metal objects as this will reduce their transmission range.
6. If the low battery icon is displayed, replace batteries in the sensors or weather station.
Changing Channel and Connecting Additional Sensors (Valid for Temperature/
Humidity/Precipitation Sensor)
1. Choose the desired channel 1, 2, or 3 for the sensor by repeatedly pressing the
button. Then,
long press the
button; the
icon will start flashing.
2. Remove the cover from the battery compartment on the rear of the sensor and set the sensor switch
to the desired sensor channel number (1, 2, 3), then insert batteries (4× 1.5 V AA). Data from the
sensor will be loaded within 3 minutes.
3. If sensor signal is not found, remove the batteries and proceed again in accordance with steps 1
and 2 or press the TX button.
Displaying Data from Multiple Sensors, Automatic Cycling through Values from
Connected Sensors
Press the
button repeatedly to display data from all connected sensors on the weather station,
one by one.
You can also activate cycling through data from all connected sensors:
1. turning on cycling
Repeatedly press the
button until the display shows the
icon.
Data from all 3 sensors will be shown automatically and repeatedly one after another.