66
GB
GB
7. INFRARED REMOTE CONTROL
Attention
In order to safeguard the proper functioning of the compressor, it is
foreseen that
- Once stopped, it will not restart earlier than 3 minutes.
- Once started, it will operate for at least 6 minutes (unless the unit
is switched off)
- Changing the modes during the operation, it may happen that the
unit does not respond immediately. Please wait 3 minutes.
- During the heating function a system of cold currents prevention is
activated. After 2-5 minutes the indoor heat exchanger will start to
make the fan working and the temperature begins to increase.
- Please wait 3 minutes before restarting the unit.
Models: Dual / Trial / Quadrial
The indoor units must be put into service in the same operational mode
or in compatibility mode according to the table below
Cooling
Dry
Heating
Fan
Cooling
√
√
X
√
Dry
√
√
X
√
Heating
X
X
√
X
Fan
√
√
X
√
√
= Norm
X= Interference
The outdoor unit always operates in the mode of the first indoor unittur-
ned/on. If a subsequent indoor unit is set in a way that interferes with
the first one, the unit that has caused the interference will be automa-
tically turned off.
Automatic
High
Average
Low
7.2 Operation in ventilation FAN ONLY
1
Press the MODE button to select the operating mode
FAN
ONLY
.
The air conditioner recirculates the ambient air without heating or
cooling. In
FAN ONLY
mode, only
HIGH, MEDIUM
and
LOW
speeds
are available.
2
Press Button
FAN SPEED
select the desired speed fan: