![emmeti RECUPERA SLIM B-110 Installation Manual And Using Instructions Download Page 27](http://html1.mh-extra.com/html/emmeti/recupera-slim-b-110/recupera-slim-b-110_installation-manual-and-using-instructions_2402015027.webp)
27
S1 S2 S3 GND
SWITCH FOR BYPASS
ACTIVATION
1 2 3
4
GND PO
T +10
N
L
V1
V2
1-10V
BALLAST
+
-
1 2 3
4
S1 S2 S3 GND
SWITCH FOR SPEED
2 SELECTION
N
L
V1
V2
GND PO
T +10
SWITCH FOR BYPASS
ACTIVATION
S1 S2 S3 GND
1 2 3
4
N
L
V2
V1
GND PO
T +10
SWITCH FOR BYPASS
ACTIVATION
5.4.1 Additional Electric Connections
The unit must be earthed.
The SLIM B-110 is wired internally from factory.
Figures below show the wiring diagrams.
WARNING
Make sure that the mains supply to the unit is disconnected before performing any installation, service, maintenance or electrical work!
WARNING
The installation and service of the unit and complete ventilation system must be performed by an authorized installer and in accordance with local rules
and regulations.
5.h
Single speed operation
5.i
Two speed operation
5.j
Two speed operation
5.k
Variable speed operation through external domotic
(BMS) system or ballast potentiometer
1 2 3
4
S1 S2 S3 GND
TWO POSITION
SWITCH OR
REMOTE SENSOR
N
L
V1
V2
GND PO
T +10
SWITCH FOR BYPASS
ACTIVATION
RECUPERA SLIM-B110
Position
W
A
Pa
m
3
/h
A (20 %)
8
0,1
15
15
B (30 %)
12
0,1
50
20
C (45 %)
20
0,2
100
40
D (60 %)
27
0,2
100
65
E (75 %)
45
0,4
100
90
F (90 %)
70
0,6
100
140
G (100 %)
95
0,8
100
177
Power consumption