72
Minute
It can be adjusted from to
Hour
It can be adjusted from to
Second
It can be adjusted from to
After adjustment of Time Range parameter , if SET1 and SET2 values
are not appropriate for this selection, SET1 and SET2 are changed according to
this selection.(E.g. If time range is 99.99 and SET1 is 45.94, there is no problem.
If time range is 99.59 and SET1 is 45.94, then SET1 is changed as 45.59 )
When count value reaches to SET1 value, Output-1 becomes active. If
Output-1 pulse time is , Output-1 does not change
condition until manual reset input is active. If Output-1 pulse time
Is not 0, at the end of the pulse time Output-1 becomes
inactive. When count value reaches to SET2 value, Output-2 becomes
active. Counting continues over SET2 value. Output-2 pulse time
Is not considered.
Count value is added to total count value when manual reset is active in
COUNTER / “TOTALIZER COUNTER” functions.
Manual Reset-1.
Device continues to count till manual reset is applied.
Output-2 pulse time is not considered.
Output Functions
(It is accessible in functions except for FREQUENCYMETER /
TACHOMETER function)
This parameter can be adjusted from to in
Batch Counter function and operates different from the other
functions.
How it operates in COUNTER / “TOTALIZER COUNTER”, TIMER
and CHRONOMETER function is explained below:
Counting direction : 0
Þ
P (Upcount)
=
Set1
0
Output-1
Set2
Reset
Output-1
Output-2
=
=
=
=
Or
Þ
i