16
15
13
14
:76mm x 34.5mm x 71mm plastic housing for panel
Mounting. Panel cutout is 71x29mm.
: NEMA 4X(IP65 at front, IP20 at rear).
: Approximately 0.20 Kg.
: Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity.
: 90 % max. (None condensing)
: Fixed installation
: II.
: II,office or workplace, none conductive pollution
: Continuous
: ON / OFF
: 14 mm Red 4 digits LED Display
: AC(Red), DC(Red),Alarm (Red),Program(Green)
7. Specifications
:AC/DC Ammeter
: 8A@250V
V
for Resistive load (Alarm output)
(Electrical life : 100.000 switching at full load)
: 230V
( %15) 50/60Hz 1.5VA,
V
( %15) 50/60Hz 1.5VA,
V
( %15) 50/60Hz 1.5VA,
V
1.5W
±
±
±
115
24
10...30V
: According to parameter value
: %1
±
: AC and RMS 0 9999
DC (1999) 9999
4 115V
( %15) 50/60Hz 1.5VA
±
5 230V
( %15) 50/60Hz 1.5VA
±
8 10 30 V
Your Technology Partner
Thank you very much for your preference to
use Emko Elektronik products, please visit our
web page to download detailed user manual.
www.emkoelektronik.com.tr
3 24V
V
V
( %15) 50/60Hz 1.5VA
±
Before commissioning the device, parameters must be set in accordance with desired use.
Incomplete or incorrect configurations can cause dangerous situations.
All order information of EDA3700 AC/DC Ammetre are given on the table at left. User may form
appropriate device configuration from information and codes that at the table and convert it to the
ordering codes. Firstly, supply voltage then other specifications must be determined. Please fill the order
code blanks according to your needs.
Please contact us, if your needs are out of the standards.
1
0
None
1
0
None
RS485
:
20mΩ
1K2Ω
,
:
Relay Output 8A@250V at resistive load ,NO+NC)
: 30 °C to +80 °C / 20 °C to + 70 °C
V
V
V
V
V
V
V
8. Ordering Information
V
Z
W
Vac
Vdc
Vdc or Vac can be applied
Ing. Petr Kotas
Rakovecká 809, 73543 Albrechtice
tel: 777884900
Eshop: