www.enviromaster.com
18
Multi-zone Heat Pump Condensing Units
S2HA DIMENSIONS AND SPECIFICATIONS
NOTE:
All EMI products are subject to ongoing development programs so design and
specifications may change without notice.
S2HA ELECTRICAL SPECIFICATIONS
MODEL
(1)
VOLTS/HZ/PHASE
FAN
COMPRESSOR 1 COMPRESSOR 2 TOTAL
AMPS
MIN. CIR.
AMPS
(2)
HACR
BRKR
RLA
HP
RLA
LRA
RLA
LRA
9900
208-230/60/1
1.8
0.33
3.4
23
3.4
23
8.6
9.5
15
2200
208-230/60/1
1.8
0.33
4.3
27
4.3
27
10.4
11.5
15
9200
208-230/60/1
1.8
0.33
3.4
23
4.3
27
9.5
10.6
15
(1) Circuit Designators: 9 = 9,000 Btuh • 2 = 12,000 Btuh (ex. - Model 9200 consists of one 9,000 Btuh compressor and one 12,000 Btuh compressor)
(2) Always refer to the rating plate for Minimum Circuit Ampacity on all multiple compressor units.
S2HA PIPING SPECIFICATIONS
SOUND DATA
SHIPPING
WEIGHT
Model#
Line Sizes
Liquid
Suction
dBA
Lbs.
9900
1/4”
1/2”
64
159
2200
1/4”
1/2”
65
197
9200
1/4”
1/2”
65
187
Easy access interconnects
on back of unit
44”
38”
15”
Electrical
connections
Front of unit
1/2” Diameter Lag Holes
4.63”
4.63”
28.74”
12.44”
3.00”