www.enviromaster.com

Side Discharge Condensers

3

proDUCt DeSCription

 

The AmericaSeries  S1C/H  and  S2C 

condensing units are, air-cooled, vertically 

arranged  side  discharge,  high  efficiency 

units designed specifically to meet  or ex

-

ceed a 13 SEER rating.  

 

The S1C 9,000-36,000 Btuh and S1H 

9,000-24,000 Btuh capacity condensing unit 

will provide cooling for a single evaporator, 

as identified in the "S1C Specifications and 

Dimensions" section on pages 23-24. 

 

The S2C 18,000 (99) - 21,000 (92) and 

23,000 (22) Btuh capacity condensing units 

will provide cooling for two evaporators, as 

identified  on page 25 in the "S2C Specifica

-

tions and Dimensions" section.  The S1C/H 

and S2C  are quiet units that can be recom

-

mended for both commercial and residential 

applications.

 

Installation  of  the  S1C/H  and  S2C 

condensing  units  is  simplified  by  a  24

control  interconnection from the evaporator 

and multiple units can be lined up in close 

proximity to an exterior wall. Service valves 

are  recessed  to  reduce  tampering  and 

all 9,000-12,000 Btuh units are equipped 

with a Duratec Performance Package that 

includes  an  oversized  suction  accumula-

tor  with  surge  baffles  and  enhanced  oil 

management, a factory installed solid core 

filter drier and loss of charge switch. A field 

installed crankcase heater is standard on 

S1H 09 &12 (Thermostatically controlled) 

models, and is available as optional equip

-

ment on other models.

• Compressor and fan motor contactor

• Run capacitor

• Loss of charge switch (09 - 12 only)

• Low voltage terminal connections

•  Large  capacity  suction  accumulator 

(09 - 12 only)

• Solid core filter drier (09 - 12 only)

• Thermostatically controlled crankcase 

heater (09 - 12 S1H’s)

• H.P.S. (High pressure switch)

- Standard on S1H’s (heat pumps)

- Standard on S1C’s 18K and above.

•  Low Ambient  controls

  for  operation 

 

down  to  32º  F 

standard, 

factory  in

-

stalled 

on all S1H’s (heat pumps)

•  Field  installed  crankcase  heater 

for  straight  cool  units  (standard  on 

9,000-12,000 Btuh S1H’s Thermostati

-

cally controlled)

•  Straight  cool  hard  start  (standard  on 

all S1H’s)

• 115

v (9,000-12,000 B

tuh only) 

• 

C

opper/copper coils (sea coast use)

•  Low Ambient controls 

for operation down 

to 32º F, specify this option for S1C or 

S2C systems (standard on S1H’s) that 

will  be  operated  in  cooling  mode  at 

outside temperatures below 60º F

 (field 

installed kit)

• Low Ambient for operation down to 0º F 

for S1C, S1H or S2C systems (consult 

factory for availability)

inStaller SUpplieD itemS

• Power wiring

• Low

 v

olt wiring (18 awg minimum)

• Secure mounting pad or foundation

•  Refrigerant  piping  (if  not  purchased 

from EMI)

• High Volt Disconnect

•  Refrigerant  for  charging  interconnect 

piping (see charge table on page 10)

itemS For ConSiDeration

low ambient controls are required 

when 

the system is asked to cool at outdoor tem

-

peratures below 60º F, this may cause dam

-

age to the compressor and coil, and  may 

Thermostatically  controlled  crankcase 
heater

 – This feature energizes the crank

-

case  heater  only  when  needed,  removes 

the  heater  from  the  electrical  circuit  at 

conditions  where  it’s  not  required,  saving 

unnecessary Watts, and increasing overall 

system efficiency. 

ControlS anD ComponentS

(Factory Installed or Supplied)

SYStem optionS

Summary of Contents for AmericaSeries S1C2

Page 1: ...ump S1C S1H Nominal Circuit Capacities S1C S1H 9 000 12 000 18 000 24 000 Btuh and S1C 30 36 Btuh Cooling Only S2C Nominal Circuit Capacities 9 000 12 000 Btuh Enviromaster International LLC 5780 Succ...

Page 2: ...he same as the electric supply to the unit The EMI AmericaSeries condens ing unit must be connected only to a properly grounded electrical sup ply Do not fail to properly ground this unit Turn off the...

Page 3: ...9 12 only Low voltage terminal connections Large capacity suction accumulator 09 12 only Solid core filter drier 09 12 only Thermostatically controlled crankcase heater 09 12 S1H s H P S High pressure...

Page 4: ...1 Place the unit on a flat concrete surface or pad if on the ground Roof mounting should use a build up platform to avoid intake of hot air from the roof 2 In areas of heavy snowfall condens ers shou...

Page 5: ...sor Accumulator Capacitor Filter Drier 3 Use only HACR type breakers or time delay fuses Select the wire size accord ing to the ampacity rating 4 To access electrical connections and wiring diagram a...

Page 6: ...he unit and into the electrical box and an chor with the strain relief fitting 7 Run wires to the high volt pigtail in the con trolboxandattachL1andL2connections Also run green wire to ground wire Hig...

Page 7: ...Use only clean refrigeration tubing Use tube benders to guard against kinking Avoid piping on wet and rainy days and insulate suction line Be certain that plastic end caps remain in place when inserti...

Page 8: ...r is 30 feet tall then a P trap is recommended at the 15 foot mark of the suction riser see Figure 1 AP trap may be fabricated using 2 street elbows and 2 regular elbow A prefab Installation Instructi...

Page 9: ...tubing and insert into fittings 5 Attach manifold set 6 Evacuate line to 500 microns or less to ensure all moisture has been removed and there are no leaks Refrigerant Refer to Refrigerant Charge Tab...

Page 10: ...tables starting on page 10 S1C REFRIGERANT CHARGE TABLE CONDENSER EVAPORATOR PAIRING LINE CHG FT FACTORY CHARGE S1C9 CAH12 25 oz 37 oz S1C2 CAH12 25 oz 40 oz S1C8 CAH24 56 oz 51 oz S1C4 CAH24 56 oz 65...

Page 11: ...sures temperatures on system supplied with Low Ambient Option the fan cycle switchshouldbejumpedoutofthecircuit temporarily to obtain accurate data Installation Instructions REFRIGERANT PROCESSING co...

Page 12: ...www enviromaster com Side Discharge Condensers 12 SINGLE ZONE OPERATION CHARTS...

Page 13: ...www enviromaster com Side Discharge Condensers 13 SINGLE ZONE OPERATION CHARTS...

Page 14: ...www enviromaster com Side Discharge Condensers 14 SINGLE ZONE OPERATION CHARTS...

Page 15: ...www enviromaster com Side Discharge Condensers 15 SINGLE ZONE OPERATION CHARTS...

Page 16: ...www enviromaster com Side Discharge Condensers 16 SINGLE ZONE Heat Pump OPERATION CHARTS...

Page 17: ...www enviromaster com Side Discharge Condensers 17 SINGLE ZONE Heat Pump OPERATION CHARTS...

Page 18: ...www enviromaster com Side Discharge Condensers 18 Dual ZONE OPERATION CHARTS...

Page 19: ...ing 9 12 Btuh units if a crankcase heater is installed power the system 24 hours before attempting to start the unit in cool weather below 60 F After doing a final system check using the Operation Cha...

Page 20: ...placed in heating mode with the set point temperature above room tempera ture the compressor and outdoor fan R Y will energize When the indoor control is satisfied and the room temper ature rises abo...

Page 21: ...fan will switch off the re versing valve will energize and the defrost board will energize the indoor electric heat relay through the W terminal After the two second defrost cycle is complete the unit...

Page 22: ...al Dimensions Model Size S2C A B C 99 32 15 36 22 92 32 15 40 Shipping Weight Model Size Lbs 99 129 22 167 92 157 S2C ELECTRICAL SPECIFICATIONS capacity Volts HZ Phase Fan Mtr Compressor Total AMPS MC...

Page 23: ...f S1C9 CAH12 9 000 13 0 79 11 7 R22 S1C2 CAH12 12 000 13 0 72 12 2 R22 S1C8 CAH24 18 000 13 0 76 12 3 R22 S1C4 CAH24 23 000 13 0 67 11 8 R22 S1C3 CAC36 30 000 14 0 82 12 0 R22 S1C6 CAC36 36 000 13 0 7...

Page 24: ...73 12 1 3 8 R22 S1H4 WLH24 23 000 20 600 13 0 8 3 71 11 9 3 5 R22 NOTE All EMI products are subject to ongoing development Design and specifications may change without notice S1C S1H Specifications a...

Page 25: ...R22 Cooling Systems with S2C Side discharge Wall Unit s Condenser Btuh SEER SHR EER Ref WLH09 WLH09 S2C99 18 000 13 0 80 11 9 R22 WLH12 WLH12 S2C22 23 000 13 0 72 12 4 R22 WLH09 WLH12 S2C92 21 000 13...

Page 26: ...Unit Performance Data Date Model Number Technician Serial Number Mode Cooling Indoor Section Notes Evaporator Entering Air DB Evaporator Entering Air WB Evaporator Leaving Air DB Evaporator Leaving Ai...

Page 27: ...Line Indoor Units outdoor Units S1C S1H Single Zone Side Discharge S2C S2H Dual Zone Side Discharge WLC WLH High Wall Air handler CAc CAH Cassette Air handler UNC UNH Universal Floor or Ceiling Air H...

Page 28: ...Phone 1 800 228 9364 Fax 1 800 232 9364 5780 Success Drive Rome NY 13440...

Reviews: