itemS For ConSiDeration
• Locate the unit as close to the indoor
section as possible. (
S
ee Tubing
Specifications chart on pape 7.)
• If the unit is used for low ambient cool
-
ing down to 32°F, this option must be
specified to prevent system damage.
• Avoid high traffic areas and prevailing
wind locations.
• Surface must be flat and level.
• Mount unit above typical snow fall
levels.
Ensure free flow of air through the unit.
Air must not recirculate from discharge to
intake. Air is drawn through the coil and
side discharged through the fan grille.
a
minimum 48" clearance is necessary for
the condenser discharge. rear intake
(coil side) clearance is 12" minimum.
Consider how power will be run to the unit
from the power source. Refrigerant piping
should be a direct line to the indoor unit.
Site preparation
1. Place the unit on a flat concrete surface
or pad if on the ground. Roof mounting
should use a build up platform to avoid
intake of hot air from the roof.
2.
In areas of heavy snowfall, condens-
ers should be set above the level of
maximum anticipated snowfall (12"
is usually adequate).
1. Loosen the screws on left and right sides
of the front panel. (Do not remove these
screws.)
2. Remove the screws on the front of the
panel.
3. T
o remove front panel:
4. S
lide front panel forward to clear side
screws and remove.
inStallation inStrUCtionS
inStallation inStrUCtionS
S1C is shown
Unit moUnting inStrUCtionS
Side discharge unit allows for per
-
manent mounting through the feet.
This is
highly recommended due to the vertical
design of the unit
.
SYStem optionS (cont.)
void the warranty. A
Field Installed Low-
Ambient kit
is good for operation down to
32º F. This is accomplished by cycling the
condenser fan on and off, which will in turn
maintain a constant low side pressure pro
-
viding a steady cooling effect and keeping
the air handler from frosting-up.
Summary of Contents for AmericaSeries S1C2
Page 12: ...www enviromaster com Side Discharge Condensers 12 SINGLE ZONE OPERATION CHARTS...
Page 13: ...www enviromaster com Side Discharge Condensers 13 SINGLE ZONE OPERATION CHARTS...
Page 14: ...www enviromaster com Side Discharge Condensers 14 SINGLE ZONE OPERATION CHARTS...
Page 15: ...www enviromaster com Side Discharge Condensers 15 SINGLE ZONE OPERATION CHARTS...
Page 16: ...www enviromaster com Side Discharge Condensers 16 SINGLE ZONE Heat Pump OPERATION CHARTS...
Page 17: ...www enviromaster com Side Discharge Condensers 17 SINGLE ZONE Heat Pump OPERATION CHARTS...
Page 18: ...www enviromaster com Side Discharge Condensers 18 Dual ZONE OPERATION CHARTS...
Page 28: ...Phone 1 800 228 9364 Fax 1 800 232 9364 5780 Success Drive Rome NY 13440...