22
This description provides the basis for the following possible wiring:
The electrical data interfaces RS232, RS485 and CL0 are implemented
by means of spring-loaded terminals.
The assignment is as follows:
RS232
Tx
Rx
RS GND
23
24
27
RS485
A(−)
B(+)
RS GND
23
24
27
CL0
+
NC
−
23
24
Output
S0: Opto-MOSFET
semiconductor relay
ES: External control
input
Input
Data
interface