~ 9 ~
v. 1.23
Section 2: WORK AREA REQUIREMENTS
As stated in section 1, the machine weighs 118 pounds, and has
some momentum when running, so it is necessary to position it on
a solid work surface that can easily support this weight, and resist
wobbling. For reference, the machine height should be set up so
that the top of the spout is at chest height of the operator.
ELECTRICAL CONNECTION:
The model CB200 machine
comes with a 72 inch long flexible power cord that has an L14 - 20
locking male plug installed on it. It MUST ONLY be connected to
a matching receptacle which has been wired to a dedicated and
fused 20-amp circuit. Your machine has a wiring tag on its cord,
as well as electrical specifications on its serial number tag on the
rear of the machine. Your electrician can also call us for technical
information if necessary during business hours.
Clearance around the machine is critical for airflow and
performance. Also, please be sure to remove all plastic protective
film from the sheet metal surfaces. The distance away from walls,
other equipment, etc. should be 8" in the rear, 18" on each side,
18" on top, and its' front open to the room. It also should remain
on the four feet it was shipped on, not only for airflow but also for
cleaning beneath it.
The surrounding area should be kept free of clutter, the floors dry,
and with at least some air circulation.