background image

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and
materials. You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for ten years from the date you purchased your ceiling fan. All other components and accessories
are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If
repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the
actual purchase price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or
removal, reinstallation and shipping of the product to Emerson Electric Co.

How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR
OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.

To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division
of Emerson Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air
Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions
or failures caused by:

Repairs by persons not authorized by Emerson Electric Co.,

Use of parts or accessories not authorized by Emerson Electric Co.,

Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or

Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:

The original purchaser or user ceases to own the product, or

The fan is moved from its original point of installation.

This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and
no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are
not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or
replacing other property which was damaged if this product does not work properly.

How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply
to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Part No. F40BP73050001

Form No. BP7305-1

U.L. Model No.: CF680

READ AND SAVE THESE INSTRUCTIONS

WESTFIELD

Net Weight:   

24.7

Lbs.

Wet Location

52” Ceiling Fan

Owner's Manual

CF680BQ00

CF680ORB00

Model No.

CF680WB00

BP7305 Westfield  6/30/06  12:10 AM  Page 1

Summary of Contents for WESTFIELD CF680BQ00

Page 1: ...rized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Elec...

Page 2: ... pounds Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for ...

Page 3: ...uld be a 3 conductor 2 wire with ground of the following sizes Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Before assembling your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check o...

Page 4: ... 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be repla...

Page 5: ...ard the four shipping retainers securing the motor hub in the motor housing NOTE Take care not to scratch the fan housing when installing the blade assemblies 3 Insert an 1 4 20 x 1 2 oval head screw supplied into each of the two recessed holes in one of the blade flanges 4 Position the blade flange on the motor hub so that the screws in the blades flange align with two threaded holes in the motor...

Page 6: ...nect the small 2 pin connector of the switch cup assembly with the small motor connector The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the latches are engaged properly 6 MOTOR FLANGE SWITCH CUP ADAPTER TIGHTEN TWO PAN HEAD SCREWS INSTALL ONE PAN HEAD SCREW LOCKWASHER Figure 3 SWITCH CUP ASSEMBLY SMALL 2 PIN CONNECTORS L...

Page 7: ... hairpin clip Figure 7 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews secure...

Page 8: ...he pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble DOWNROD CEILING COVER PIN HANGERBALL SETSCREW Figure 10 21 The fan comes with blue black and white leads that are 80 long B...

Page 9: ...attached to the outlet box Figure 13 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 12 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 12 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are n...

Page 10: ...ll switches or optional Emerson fan light controls you will need a three wire with ground conductor cable between the ceiling and wall outlet boxes This will allow you to operate the fan housing lights and an optional Emerson Light Fixture if installed from one switch control and the ceiling fan from a separate switch Refer to Figure 14 and proceed as follows a Connect the green grounding lead fro...

Page 11: ...d proceed as follows a Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the supply grounding conductor this may be a bare wire or wire with green colored insulation Securely connect wires with a wire connector supplied b Securely connect the fan motor white wire to the supply white neutral wire using a wire connector supplied c Securely ...

Page 12: ...UD 2 CEILING COVER KNURLED KNOB 2 LOCKWASHER 2 12 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING BLACK FAN WIRE LISTED OUTLET BOX GREEN WIRE GROUND FROM HANGER BRACKET WHITE GREEN WIRE GROUND FROM HANGER BALL GROUND WIRE BLUE BLACK LISTED WIRE CONNECTOR 3 GENERAL PURPOSE ON O...

Page 13: ...TCH UNDER WATER RESISTANT RUBBER BOOT Figure 17 UPPER HOUSING COVER 7 WATT MAX CANDELABRA BULB UPPER HOUSING SETSCREWS 3 COLLAR Figure 18 To replace a burned out light bulb raise the upper housing cover on the downrod up to the ceiling cover Figure 18 Loosen the setscrews in the upper housing collar then raise the cover and remove the defective bulb from the socket Screw in the replacement 7 watt ...

Page 14: ... parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents ar...

Page 15: ...or housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling 1 Raise upper housing cover and excessively are not tightened securely and upper housing then tighten setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check to be sure screws flanges to motor are loose whic...

Page 16: ...l parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 16 BP7305 Westfield 6 30 06 12 10 AM Page 16 ...

Page 17: ...5 Coupling Chain 2 16 Cover Ceiling 762649 BQ 762649 ORB 762649 WB 17 Cover Upper Housing 762940 BQ 762940 ORB 762940 WB 18 Housing Upper 762941 BQ 762941 ORB 762941 WB 19 Glass Center 762942 762942 762942 20 Flange Set full set for one fan 762945 BQ 762945 ORB 762945 WB 21 Blade Set full set for one fan 762947 762947 762947 22 Adapter Switch Cup 762949 762949 762949 23 Cup Assembly Switch 762950 ...

Page 18: ...18 Notes BP7305 Westfield 6 30 06 12 10 AM Page 18 ...

Page 19: ...19 Notes BP7305 Westfield 6 30 06 12 10 AM Page 19 ...

Page 20: ...Part No F40BP73050001 Printed in China 07 06 Form No BP7305 1 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 BP7305 Westfield 6 30 06 12 10 AM Page 20 ...