background image

5

IMPORTANT: The side of the fan blade
having the rib line MUST be facing
upward as shown in Figure 1.

1. Mount the fan blades to the blade

flanges using three 10-32 x .30” pan
head screws and three flat washers
(screws and washers supplied)
(Figure 1).

How to Assemble Your

Ceiling Fan

Turning off wall switch is not sufficient.
To avoid possible electrical shock, be
sure electricity is turned off at the main
fuse or circuit breaker box before wiring.
All wiring must be in accordance with
National and Local codes and the ceiling
fan must be properly grounded as a
precaution against possible electrical
shock.

!

WARNING

To reduce the risk of personal injury, do
not bend the blade flange when installing
the blade flanges, balancing the blades or
cleaning the fan. Do not insert foreign
objects in between rotating fan blades.

!

WARNING

10-32  x .30" 
PAN HEAD 
SCREWS (3)

FLAT 
WASHERS (3)

RIB LINE (THIS SIDE 
OF BLADE UP)

FAN BLADE

BLADE 
FLANGE

Figure 1

2. Remove and discard the four shipping

retainers securing the motor hub in the
motor housing.

NOTE: Take care not to scratch the fan
housing when installing the blade
assemblies.

3. Insert an 1/4-20 x 1/2” oval head screw

(supplied) into each of the two
recessed holes in one of the blade
flanges.

4. Position the blade flange on the motor

hub so that the screws in the blades
flange align with two threaded holes in
the motor hub (Figure 2). Loosely
tighten the screws at this time. Repeat
this procedure for the remaining four
blade assemblies.

5. Gently snug all flange screws to the

motor hub, working around the hub in a
clockwise sequence. Next, securely
tighten all flange screws, again working
in a clockwise sequence. Failure to
follow this procedure could result in fan
wobble. This completes the blade
installation.

1/4-20 x 1/2" OVAL 
HEAD SCREWS (2)

BLADE 
FLANGE

MOTOR FLANGE

REMOVE ONE PAN HEAD 
SCREW/LOCKWASHER

MOTOR HUB

Figure 2

!

WARNING

To reduce the risk of personal injury, do
not bend the blade flanges when
installing the flanges, balancing the
blades or cleaning the fan. Do not insert
foreign objects between rotating fan
blades.

BP7305 Westfield  6/30/06  12:10 AM  Page 5

Summary of Contents for WESTFIELD CF680BQ00

Page 1: ...rized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Elec...

Page 2: ... pounds Use only U L outlet boxes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for ...

Page 3: ...uld be a 3 conductor 2 wire with ground of the following sizes Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 Before assembling your ceiling fan refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check o...

Page 4: ... 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be repla...

Page 5: ...ard the four shipping retainers securing the motor hub in the motor housing NOTE Take care not to scratch the fan housing when installing the blade assemblies 3 Insert an 1 4 20 x 1 2 oval head screw supplied into each of the two recessed holes in one of the blade flanges 4 Position the blade flange on the motor hub so that the screws in the blades flange align with two threaded holes in the motor...

Page 6: ...nect the small 2 pin connector of the switch cup assembly with the small motor connector The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the latches are engaged properly 6 MOTOR FLANGE SWITCH CUP ADAPTER TIGHTEN TWO PAN HEAD SCREWS INSTALL ONE PAN HEAD SCREW LOCKWASHER Figure 3 SWITCH CUP ASSEMBLY SMALL 2 PIN CONNECTORS L...

Page 7: ... hairpin clip Figure 7 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews secure...

Page 8: ...he pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble DOWNROD CEILING COVER PIN HANGERBALL SETSCREW Figure 10 21 The fan comes with blue black and white leads that are 80 long B...

Page 9: ...attached to the outlet box Figure 13 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 12 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 12 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are n...

Page 10: ...ll switches or optional Emerson fan light controls you will need a three wire with ground conductor cable between the ceiling and wall outlet boxes This will allow you to operate the fan housing lights and an optional Emerson Light Fixture if installed from one switch control and the ceiling fan from a separate switch Refer to Figure 14 and proceed as follows a Connect the green grounding lead fro...

Page 11: ...d proceed as follows a Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the supply grounding conductor this may be a bare wire or wire with green colored insulation Securely connect wires with a wire connector supplied b Securely connect the fan motor white wire to the supply white neutral wire using a wire connector supplied c Securely ...

Page 12: ...UD 2 CEILING COVER KNURLED KNOB 2 LOCKWASHER 2 12 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling WARNING BLACK FAN WIRE LISTED OUTLET BOX GREEN WIRE GROUND FROM HANGER BRACKET WHITE GREEN WIRE GROUND FROM HANGER BALL GROUND WIRE BLUE BLACK LISTED WIRE CONNECTOR 3 GENERAL PURPOSE ON O...

Page 13: ...TCH UNDER WATER RESISTANT RUBBER BOOT Figure 17 UPPER HOUSING COVER 7 WATT MAX CANDELABRA BULB UPPER HOUSING SETSCREWS 3 COLLAR Figure 18 To replace a burned out light bulb raise the upper housing cover on the downrod up to the ceiling cover Figure 18 Loosen the setscrews in the upper housing collar then raise the cover and remove the defective bulb from the socket Screw in the replacement 7 watt ...

Page 14: ... parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents ar...

Page 15: ...or housing are snug not over tight 3 Fan wobbles 1 Setscrews in motor coupling 1 Raise upper housing cover and excessively are not tightened securely and upper housing then tighten setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check to be sure screws flanges to motor are loose whic...

Page 16: ...l parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 16 BP7305 Westfield 6 30 06 12 10 AM Page 16 ...

Page 17: ...5 Coupling Chain 2 16 Cover Ceiling 762649 BQ 762649 ORB 762649 WB 17 Cover Upper Housing 762940 BQ 762940 ORB 762940 WB 18 Housing Upper 762941 BQ 762941 ORB 762941 WB 19 Glass Center 762942 762942 762942 20 Flange Set full set for one fan 762945 BQ 762945 ORB 762945 WB 21 Blade Set full set for one fan 762947 762947 762947 22 Adapter Switch Cup 762949 762949 762949 23 Cup Assembly Switch 762950 ...

Page 18: ...18 Notes BP7305 Westfield 6 30 06 12 10 AM Page 18 ...

Page 19: ...19 Notes BP7305 Westfield 6 30 06 12 10 AM Page 19 ...

Page 20: ...Part No F40BP73050001 Printed in China 07 06 Form No BP7305 1 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 BP7305 Westfield 6 30 06 12 10 AM Page 20 ...

Reviews: