background image

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling
fan against all defects in workmanship and materials. You must be the original purchaser or user of the product
to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and
accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH
RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other
accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable
time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase price of your fan.
We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or
removal, reinstallation and shipping of the product to Emerson Electric Co.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY
SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory
or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to

Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136.
Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest

authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized
service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit
since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does
not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal

wear and tear.

• Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are

voided when:

• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other
written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any
warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS
WARRANTY AND EMERSON ELECTRIC CO. IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING
INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such
damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of
repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above
exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.

Part No. F40BP73590001

Printed in China  09/07

Form No. BP7359-1

Air Comfort Products

DIVISION OF EMERSON ELECTRIC CO.

8100 W. Florissant ¥ St. Louis, MO 63136

U.L. Model No.: CF240

BP7359 VININGS CF240  9/19/07  11:13 AM  Page 20

Summary of Contents for VININGS CF240ATB00

Page 1: ... BP7359 1 U L Model No CF240 READ AND SAVE THESE INSTRUCTIONS Net Weight 27 0 Lbs VININGS Ceiling Fan Owner s Manual CF240ATB00 Antique Bronze with Dark Cherry Walnut Blades Model Number BP7359 VININGS CF240 9 19 07 11 13 AM Page 1 ...

Page 2: ...ixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 8 downrod supplied must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental c...

Page 3: ...e assembling your ceiling fan refer to section on proper method of wiring your fan page 11 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have b...

Page 4: ...ber washer 12 One hex wrench NOTE Place the parts from the loose parts bags in a small container to keep them from being lost 2 Remove the fan motor and housing assembly from the protective plastic bag Place the fan assembly into the lower foam pad with the bottom of the motor facing up The lower foam pad serves as a holder for the fan during the first stages of assembly A C F E J H G K N M L O P ...

Page 5: ...dures IMPORTANT Before assembling your ceiling fan refer to sections Setting Operating Frequency of Wall Control and Receiver and Installation of Wall Control page 13 These sections instruct you how to a Set the operating frequency of the fan light wall control and the remote control receiver and b Install the fan light wall control in the wall box You will then be ready to proceed with the assemb...

Page 6: ...ded and must be mated correctly color to color before they can be engaged Make sure the connectors are engaged properly 6 10 24 x 8mm TRUSS HEAD SCREWS 3 FLAT WASHERS 3 FAN BLADE BLADE FLANGE Figure 1 1 4 20 x 13mm OVAL HEAD SCREWS 2 MOTOR FLANGE BLADE FLANGE MOTOR HUB REMOVE AND RETAIN ONE PAN HEAD SCREW LOCKWASHER LOOSEN TWO PAN HEAD SCREWS Figure 2 REINSTALL ONE PAN HEAD SCREW LOCKWASHER LIGHT ...

Page 7: ...t fitter assembly positioned in the gap and the fan assembly resting on the fan blade assemblies PARTIALLY ASSEMBLED FAN STYROFOAM PACKAGING 6 TO 8 INCH GAP Figure 6 REMOVE AND RETAIN THREE PAN HEAD SCREW LOCKWASHERS LIGHT FITTER CONNECTOR MOTOR CONNECTOR LIGHT FITTER ASSEMBLY Figure 4 REINSTALL THREE PAN HEAD SCREW LOCKWASHERS LIGHT FITTER ASSEMBLY LIGHT FITTER ADAPTER Figure 5 PIN HANGER BALL SE...

Page 8: ...nstalled as shown in Figure 8 could result in the fan falling 13 Tighten the two upper setscrews Figure 8 securely while pulling up on the downrod NOTE The setscrews must be properly installed as described above or fan wobble could result 14 Position the three scrolls on the decorative coupling cover so that they are vertical then tighten the nuts on the inside of the coupling cover Make sure the ...

Page 9: ...ly 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 from end of leads 18 You have now completed the initial assembly of your new ceiling fan You can now proceed with hanging and wiring your fan 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 12 How to Hang Your Ceiling Fan The ...

Page 10: ...outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX NOTE CEILING COVER SUPPL Y WIR...

Page 11: ...tors except for the ground wire 2 Refer to Figures 14 and 15 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC ...

Page 12: ...E GROUND FROM HANGER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE WHITE BLUE EMERSON HI MED LOW FAN OFF LIGHT ON OFF Figure 15 3 Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket Position the antenna wire on top of the receiver 4 Screw the two 1 1 4 threaded studs supplied ...

Page 13: ...ceiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 In the rece...

Page 14: ...e in wall box Securely connect wires with wire connector supplied 6 Screw wall control into wall box and install decorator style faceplate included Leave wall control in OFF mode until fan installation is completed 7 Refer to page 5 and complete the ceiling fan installation Do not connect any neutral white wire to this control Incorrect wiring will damage this control WARNING Do not connect any ne...

Page 15: ...n at the service panel NOTE Make sure that the ON OFF slide switch on the Fan Light Wall Control is in the ON position 2 To set the desired fan speed press the HI MED or LOW buttons to operate your fan on high medium or low speed Figure 23 EMERSON HI MED LOW FAN OFF LIGHT ON OFF Figure 23 3 To turn your fan off press the OFF button 4 To set the level of light brightness press and hold the LIGHT bu...

Page 16: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which ...

Page 17: ...les 1 Setscrews in motor coupling are 1 Raise decorative downrod cover excessively not tightened securely and coupling cover and tighten setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check to be sure screws which flanges to motor are loose attach the fan blade flanges to the motor ...

Page 18: ...terial be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 18 U L Model No CF240 BP7359 VININGS CF240 9 19 07 11 13 AM Page 18 ...

Page 19: ...17 Cover Ceiling 763004 ATB 18 Downrod Scroll Decorative 763007 ATB 19 Coupling Cover Decorative 763005 ATB 20 Lower Scroll Decorative 3 763006 ATB 21 Flange Set full set for one fan 763010 ATB 22 Blade Set full set for one fan 762635 16 23 Adapter Light Fitter 763013 ATB 24 Fitter Assembly Light 763014 25 Glass Lower 763016 26 Cap Decorative 763019 ATB 27 Nut Finial 763020 ATB 28 Harness Assembly...

Page 20: ...tory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by...

Reviews: