Place the second wall control into the
wall box. Screw in place and install
decorator style faceplate (included).
Leave switch in “OFF” mode until fan
installation is completed. 

10. Refer to page 5 and complete the

ceiling fan installation . 

STANDARD WIRING FOR EXISTING
3-WAY CONTROL

15

HOT

BLK

FAN/LIGHT
WALL CONTROL

BLK

TRAVELER WIRES

BLK

BLK

BLACK

LOAD

BLACK

LOAD

TRAVELER WIRES

HOT

BLK

EXISTING

WALL  CONTROL

EMERSON

®

EMERSON

®

HI

MED

LOW

FAN  OFF

LIGHT

ON

OFF

HI

MED

LOW

FAN  OFF

LIGHT

ON

OFF

Figure 22

Operating Your

Ceiling Fan

IMPORTANT

Fan installation must be completed,
including the installation of the fan
blades, before testing of the remote
control.

Your Fan/Light Wall Control (Figure 23)
has full control of your fan and light.
However, airflow direction is controlled by
a slide switch on the light fitter.

1. Restore electrical power to the outlet

box by turning the electricity on at the
service panel.

NOTE: Make sure that the ON/OFF slide
switch on the Fan/Light Wall Control is
in the ON position.

2. To set the desired fan speed, press the

HI, MED, or LOW buttons to operate
your fan on high, medium, or low speed
(Figure 23).

EMERSON

®

HI

MED

LOW

FAN  OFF

LIGHT

ON

OFF

Figure 23

3. To turn your fan off, press the OFF

button.

4. To set the level of light brightness,

press and hold the LIGHT button. The
light brightness will continue to
increase then decrease while the
button is held down. When the light is
at the desired brightness, release the
button.

5. To turn the light on and off, press and

release the LIGHT button. The light will
turn on at the light level previously set
(see step 4).

6. If airflow is desired in the opposite

direction, turn the fan off and wait for
the blades to stop turning. Remove the
lower glass (Figure 17), then slide the
reversing switch (located on the light
fitter) to the opposite position and turn
the fan on again. The blades will turn in
the opposite direction and reverse the
airflow.

U.L. Model No.: CF240

BP7359 VININGS CF240  9/19/07  11:13 AM  Page 15

Summary of Contents for VININGS CF240ATB00

Page 1: ... BP7359 1 U L Model No CF240 READ AND SAVE THESE INSTRUCTIONS Net Weight 27 0 Lbs VININGS Ceiling Fan Owner s Manual CF240ATB00 Antique Bronze with Dark Cherry Walnut Blades Model Number BP7359 VININGS CF240 9 19 07 11 13 AM Page 1 ...

Page 2: ...ixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 8 downrod supplied must be used for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental c...

Page 3: ...e assembling your ceiling fan refer to section on proper method of wiring your fan page 11 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have b...

Page 4: ...ber washer 12 One hex wrench NOTE Place the parts from the loose parts bags in a small container to keep them from being lost 2 Remove the fan motor and housing assembly from the protective plastic bag Place the fan assembly into the lower foam pad with the bottom of the motor facing up The lower foam pad serves as a holder for the fan during the first stages of assembly A C F E J H G K N M L O P ...

Page 5: ...dures IMPORTANT Before assembling your ceiling fan refer to sections Setting Operating Frequency of Wall Control and Receiver and Installation of Wall Control page 13 These sections instruct you how to a Set the operating frequency of the fan light wall control and the remote control receiver and b Install the fan light wall control in the wall box You will then be ready to proceed with the assemb...

Page 6: ...ded and must be mated correctly color to color before they can be engaged Make sure the connectors are engaged properly 6 10 24 x 8mm TRUSS HEAD SCREWS 3 FLAT WASHERS 3 FAN BLADE BLADE FLANGE Figure 1 1 4 20 x 13mm OVAL HEAD SCREWS 2 MOTOR FLANGE BLADE FLANGE MOTOR HUB REMOVE AND RETAIN ONE PAN HEAD SCREW LOCKWASHER LOOSEN TWO PAN HEAD SCREWS Figure 2 REINSTALL ONE PAN HEAD SCREW LOCKWASHER LIGHT ...

Page 7: ...t fitter assembly positioned in the gap and the fan assembly resting on the fan blade assemblies PARTIALLY ASSEMBLED FAN STYROFOAM PACKAGING 6 TO 8 INCH GAP Figure 6 REMOVE AND RETAIN THREE PAN HEAD SCREW LOCKWASHERS LIGHT FITTER CONNECTOR MOTOR CONNECTOR LIGHT FITTER ASSEMBLY Figure 4 REINSTALL THREE PAN HEAD SCREW LOCKWASHERS LIGHT FITTER ASSEMBLY LIGHT FITTER ADAPTER Figure 5 PIN HANGER BALL SE...

Page 8: ...nstalled as shown in Figure 8 could result in the fan falling 13 Tighten the two upper setscrews Figure 8 securely while pulling up on the downrod NOTE The setscrews must be properly installed as described above or fan wobble could result 14 Position the three scrolls on the decorative coupling cover so that they are vertical then tighten the nuts on the inside of the coupling cover Make sure the ...

Page 9: ...ly 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 from end of leads 18 You have now completed the initial assembly of your new ceiling fan You can now proceed with hanging and wiring your fan 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 12 How to Hang Your Ceiling Fan The ...

Page 10: ...outlet box are not securely attached the fan could wobble or fall WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX NOTE CEILING COVER SUPPL Y WIR...

Page 11: ...tors except for the ground wire 2 Refer to Figures 14 and 15 and connect the receiver wires to the supply wires and the fan motor wires as follows a Securely connect the green grounding wires from the hanger ball and the hanger bracket to the supply grounding conductor this may be a bare wire or a wire with green insulation b Securely connect the supply white neutral wire to the receiver white AC ...

Page 12: ...E GROUND FROM HANGER BALL AND HANGER BRACKET TWO CONDUCTOR CABLE WITH GROUND BLACK HOT WHITE GROUND TO 120 VOLT SUPPLY WHITE BLUE WHITE BLUE EMERSON HI MED LOW FAN OFF LIGHT ON OFF Figure 15 3 Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket Position the antenna wire on top of the receiver 4 Screw the two 1 1 4 threaded studs supplied ...

Page 13: ...ceiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 In the rece...

Page 14: ...e in wall box Securely connect wires with wire connector supplied 6 Screw wall control into wall box and install decorator style faceplate included Leave wall control in OFF mode until fan installation is completed 7 Refer to page 5 and complete the ceiling fan installation Do not connect any neutral white wire to this control Incorrect wiring will damage this control WARNING Do not connect any ne...

Page 15: ...n at the service panel NOTE Make sure that the ON OFF slide switch on the Fan Light Wall Control is in the ON position 2 To set the desired fan speed press the HI MED or LOW buttons to operate your fan on high medium or low speed Figure 23 EMERSON HI MED LOW FAN OFF LIGHT ON OFF Figure 23 3 To turn your fan off press the OFF button 4 To set the level of light brightness press and hold the LIGHT bu...

Page 16: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which ...

Page 17: ...les 1 Setscrews in motor coupling are 1 Raise decorative downrod cover excessively not tightened securely and coupling cover and tighten setscrews securely 2 Setscrew in the hanger ball 2 Tighten the setscrew in the downrod assembly is loose hanger ball downrod assembly 3 Screws securing fan blade 3 Check to be sure screws which flanges to motor are loose attach the fan blade flanges to the motor ...

Page 18: ...terial be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 18 U L Model No CF240 BP7359 VININGS CF240 9 19 07 11 13 AM Page 18 ...

Page 19: ...17 Cover Ceiling 763004 ATB 18 Downrod Scroll Decorative 763007 ATB 19 Coupling Cover Decorative 763005 ATB 20 Lower Scroll Decorative 3 763006 ATB 21 Flange Set full set for one fan 763010 ATB 22 Blade Set full set for one fan 762635 16 23 Adapter Light Fitter 763013 ATB 24 Fitter Assembly Light 763014 25 Glass Lower 763016 26 Cap Decorative 763019 ATB 27 Nut Finial 763020 ATB 28 Harness Assembly...

Page 20: ...tory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by...

Reviews: