OPERATION

Model 3650B Series pressure relief valves

When the internal tank pressure approaches 
the valve setting, the pallet begins to lift. as the 
pressure exceeds the valve setting, the pallet 
lifts off the seat ring. excess product vapor is 
allowed to vent through the pipe away system 
adapter, relieving the over pressure condition. 
The pallet automatically re-seats as the tank 
pressure drops below the valve setting.

Model 3600B and 3650B Series vacuum 
relief valves

When a vacuum within the tank approaches 
the valve setting, the pallet begins to lift. as 
the vacuum exceeds the valve setting, the 
pallet lifts off the seat ring. atmospheric or dry 
air is allowed to flow into the tank, relieving 
the excess vacuum condition. The pallet 
automatically re-seats as the tank vacuum 
drops below the valve setting.

fiGure 2. preSSure coNTrol operaTioN

fiGure 3. vacuum coNTrol operaTioN

TABLE 3 - 3650B SERIES PRESSURE SETTING

Series

Pressure Setting Low Range

Pressure Setting High Range

3650B

0.3 to 16

*

 osig / 1.3 to 68.9* mbar 

16

*

 to 32 osig / 68.9* to 138 mbar

*10 osig / 43.1 mbar for 2 and 3 inchec sizes.

TABLE 4 - 3600B AND 3650B SERIES VACUUM SETTING

Series

Vacuum Setting Low Range

Vacuum Setting High Range

3600B

0.3 to 16

(1)

 osig / 1.3 to 68.9

(1)

 mbar

16

(1)

 to 32 osig / 68.9

(1)

 to 138 mbar

3650B

0.3 to 16

(2)

osig / 1.3 to 68.9

(2)

 mbar

16

(2)

 to 32 osig / 68.9

(2)

 to 138 mbar

NOTES

1. 10 osig / 43.1 mbar for 2, 3 and 4 inches sizes
2. 10 osig / 43.1 mbar for 2 and 3 inches sizes

VAREC 

3600B/3650B SerieS preSSure or vacuum relief valveS

INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Summary of Contents for VAREC 3600B Series

Page 1: ...ons of Remedy in the contract between Emerson and our customer SAFETY PRECAUTIONS Read and understand this instruction manual before installing operating or performing maintenance on 3600B and 3650B Series pressure or vacuum relief valves Follow all precautions and warnings noted herein when installing operating or performing maintenance on this equipment WARNING Relief valve must be isolated from...

Page 2: ... Code Flange Drilling F 150 ANSI Drilling Fractional Studs D PN 16 DIN Drilling Metric Studs Code Flange Face F Flat Face Flange R Raised Face Flange Not Available with Aluminum Code Gasket o ring material O Standard B Nitrile NBR T Polytetrafluoroethylene PTFE V Fluorocarbon FKM Code Retainer Screen Material P Plastic S Stainless steel Code Vacuum Setting Ranges 02 Low 04 High NOTE Materials for ...

Page 3: ...ile NBR V Fluorocarbon FKM Code Flange Drilling F 150 ANSI Drilling Fractional Studs D PN 16 DIN Drilling Metric Studs Code Flange Face F Flat Face Flange R Raised Face Flange Not Available with Aluminum Code Gasket O ring material O Standard B Nitrile NBR T PTFE V Fluorocarbon FKM Code Retainer Screen Material P Plastic S Stainless steel Code Pressure or Vacuum Setting Ranges 02 Low 04 High NOTE ...

Page 4: ...to the tank relieving the excess vacuum condition The pallet automatically re seats as the tank vacuum drops below the valve setting FIGURE 2 PRESSURE CONTROL OPERATION FIGURE 3 VACUUM CONTROL OPERATION TABLE 3 3650B SERIES PRESSURE SETTING Series Pressure Setting Low Range Pressure Setting High Range 3650B 0 3 to 16 osig 1 3 to 68 9 mbar 16 to 32 osig 68 9 to 138 mbar 10 osig 43 1 mbar for 2 and ...

Page 5: ...s through the center of the mesh screen Push up on the pallet then lower it onto the seat Pallet should move freely and rest flat on the seat ring 5 With valve in level position check the pallet operation on Model 3650B Reach up through the bottom flange opening and carefully push up on the pallet then lower it onto the seat Pallet should move freely and rest flat on the seat ring 6 Mount the valv...

Page 6: ...ne compound Avoid scoring or removing excessive amounts of material c Clean all compound from valve parts d Hand buff seat with a medium grade Scotch Brite 7447 pad and light oil CAUTION Whenever the cover is removed and reinstalled the end of the pallet stem must engage the stem guide chamber in the cover for proper pallet seating and valve operation CALIBRATION ADJUSTMENT To verify the settings ...

Page 7: ...0 318 14 19 360 10 11 19 284 4 00 102 14 06 357 17 94 456 12 13 62 346 5 44 138 16 88 429 22 38 568 VAREC 3600B 3650B Series pressure or vacuum relief valves INSTRUCTION OPERATION AND MAINTENANCE MANUAL FIGURE 4 MODEL 3600B VACUUM RELIEF VALVE LOW SETTING DRILLING PER ANSI CLASS 125 F F TABLE 7 MODEL 3600B LOW SETTING SIZES AND DIMENSIONS Size A in mm B in mm C in mm D in mm ...

Page 8: ...69 399 14 19 360 10 11 19 284 4 00 102 16 50 419 17 94 456 12 13 62 346 5 44 138 18 56 471 22 38 568 VAREC 3600B 3650B Series pressure or vacuum relief valves INSTRUCTION OPERATION AND MAINTENANCE MANUAL FIGURE 5 MODEL 3600B VACUUM RELIEF VALVE HIGH SETTING DRILLING PER ANSI CLASS 125 F F TABLE 8 MODEL 3600B HIGH SETTING SIZES AND DIMENSIONS Size A in mm B in mm C in mm D in mm ...

Page 9: ...475 17 94 456 10 12 13 62 346 12 75 324 24 12 613 22 38 568 12 14 15 38 391 16 69 424 29 88 759 25 38 645 VAREC 3600B 3650B Series pressure or vacuum relief valves INSTRUCTION OPERATION AND MAINTENANCE MANUAL TABLE 9 MODEL 3650B LOW SETTING SIZES AND DIMENSIONS Size A in mm B in mm C in mm D in mm E F FIGURE 6 MODEL 3650B PRESSURE OR VACUUM RELIEF VALVE LOW SETTING DRILLING PER ANSI CLASS 125 F F ...

Page 10: ...536 17 94 456 10 12 13 62 346 12 75 324 25 81 656 22 38 568 12 14 15 38 391 16 69 424 29 88 759 25 38 645 VAREC 3600B 3650B Series pressure or vacuum relief valves INSTRUCTION OPERATION AND MAINTENANCE MANUAL FIGURE 7 MODEL 3650B PRESSURE OR VACUUM RELIEF VALVE HIGH SETTING DRILLING PER ANSI CLASS 125 F F TABLE 10 MODEL 3650B HIGH SETTING SIZES AND DIMENSIONS Size A in mm B in mm C in mm D in mm E...

Page 11: ... B12743 093 B12744 093 B13288 093 4 Cover and spacer gasket All Nitrile NBR 02 11380 075 02 11381 075 02 11382 075 02 11383 075 02 11384 075 02 11385 075 02 11386 075 5 Guide post All 316 SST 02 11015 106 02 11015 306 02 11432 106 B16553 406 B16553 206 B16553 506 02 11433 106 6 O ring All Nitrile NBR P014 03 285 P014 03 273 P014 03 286 P014 03 287 P014 03 288 P014 03 289 P014 03 290 TABLE 11 REPLA...