Unidrive M300 Quick Start Guide
17
Issue Number: 4
Figure 4-5 Pr 00.005 = Preset (50 and 60 Hz)
Figure 4-6 Pr 00.005 = Pad (50 and 60 Hz)
1
2
4
0V
Voltage speed reference
input (AI 1)
Reference select
5
7
Analog output 1
(motor frequency)
+ 10 V output
Digital output
(zero frequency)
9
10
11
Unassigned
12
13
14 Reference select
Run forward
+ 24 V output
10k
Run reverse
Terminal 5
Terminal 14
Reference selected
0
0
1
1
0
1
0
1
Preset speed 1 (
)
01.021
Preset speed 2 (
)
01.022
Preset speed 3 (
)
01.023
Preset speed 4 (
)
01.024
1
2
0V
Voltage speed reference
input (AI 1)
7
Analog output 1
(motor frequency)
10k
9
10
11
Digital output
(zero frequency)
Unassigned
12
13
14
Analog input 1/
input 2 select
Run forward
+ 24 V output
Run reverse
4
5
+ 10 V output
Voltage speed reference
input (AI 2)
10k
When Pr
00.005
is set to Pad, to run
in reverse:
•
Set Pr
00.017
to On
The Keypad reference can now be
set to a negative frequency to run the
motor in the reverse direction.