Restoring Factory Settings
If ther
e are reported errors or configuration issues, the user may restore factory
settings to return the thermostat to its default parameters.
Procedure
➤
Remove the faceplate of the thermostat;
➤
With the thermostat on, press the CONFIG button located on the control
board inside the thermostat.
➤
Press the F|C button twice, or until you reach the equipment code
configuration screen.
➤
Press and hold the CONFIG button. The screen wil display “RST”
➤
Press the F|C button.
➤
If the master reset was successful, the thermostat will display “VRD” and then
“SETUP” on the screen. The thermostat must now be re-configured. Please
refer to pages thermostat configuration section of this manual.
Contact Verdant technical support if the issues are not resolved.
Troubleshooting Guide
APPENDIX 1 - Energy Saving Presets
Level
0
Level
1
Level
2
Level
3
Level
4
Level
5
Fan Control Mode
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
1st Stage Differential Heat
0.5
0.5
0.5
0.5
0.5
0.5
2nd Stage Differential Heat
1
1
1
2
2
2
1st Stage Differential Cool
0.5
0.5
0.5
0.5
0.5
0.5
Guest Occupancy Threshold
0
5
5
5
5
5
Night Occupancy Threshold
1
1
1
1
1
1
Force 2nd Stage Heating After
30
30
30
30
30
30
Night Occupancy Start
18
19
20
21
22
23
Night Occupancy End
12
11
10
9
8
7
Recovery Time
0
15
20
25
30
0
Recovery Temperature Heat
70
69
68
67
66
65
Setback Delay - Heat
0
30
25
20
15
10
Minimum Setback Temperature
67
66
65
64
63
62
Setback Delay - Cool
0
30
25
20
15
10
Maximum Setback Temperature
72
74
76
78
80
82
Recovery Temperature Cool
71
72
73
74
75
76
Minimum Set point
64
64
65
66
67
68
Maximum Set point
82
82
80
78
76
74
Temperature Control Mode
AUTO
AUTO
AUTO
AUTO
AUTO
AUTO
Auto Changeover Set Point
Offset
Dead Band)
1
1
1
1
1
1
Auto Restore
OFF
ON
ON
ON
ON
ON
Setback Set Points
OFF
ON
ON
ON
ON
ON
Automatic Humidity Control
ON
ON
ON
ON
ON
ON
Temperature Calibration
0
0
0
0
0
0