1.2.3
Output configuration
Code
Outputs
Fault relay
Alarm relay
Auxiliary relay
Current type
1A
Analog/HART
®
/
RS-485/relays
(fault, alarm)
Normally closed
Normally open
N/A
Sink
★
2A
Analog/HART/
RS-485/relays
(fault, alarm)
Normally closed
Normally open,
normally closed
N/A
Source
★
3A
Analog/HART/
RS-485/relays
(fault, alarm)
Normally open
Normally open,
normally closed
N/A
Source
★
1R
RS-485/relays
(fault, alarm,
auxiliary)
Normally closed
Normally open
Normally open
N/A
★
2R
RS-485/relays
(fault, alarm,
auxiliary)
Normally open
Normally open
Normally open
N/A
★
1.2.4
Housing style
Code
Material
Conduit entry
6A
Aluminum
¾
-in. national pipe thread (NPT)
★
8A
Aluminum
M25
★
6S
Stainless steel
¾
-in. NPT
★
8S
Stainless steel
M25
★
(1)
Aluminum housing is not available in FM/CSA product certification.
1.2.5
Temperature
Code
Description
1
167 °F (75 °C)
★
2
185 °F (85 °C)
★
1.2.6
Product certifications
Code
Description
A1
ATEX and IECEx flameproof
★
A2
FM and CSA flameproof
★
E2
InMetro flameproof
★
EM
Technical Regulations Customs Union (EAC) flameproof
★
Reference Manual
Introduction
00809-0100-4976
June 2021
Rosemount 975HR
9
Legacy