IMPORTANT NOTICE

This installation guide provides basic guidelines for the Rosemount 848T. It does not 
provide instructions for detailed configuration, diagnostics, maintenance, service, 
troubleshooting, or installations. Refer to the Rosemount 848T reference manual 
(Document Number 00809-0100-4848) for more instruction. The manual and this QIG are 
also available electronically on www.rosemount.com.

WARNING

Explosions could result in death or serious injury:

 

Installation of this transmitter in an explosive environment must be in accordance with the 
appropriate local, national, and international standards, codes, and practices. Please 
review the Product Certifications section for any restrictions associated with a safe 
installation.

• Before connecting a Rosemount 375 Field Communicator in an explosive 

atmosphere, ensure the instruments are installed in accordance with intrinsically safe 
or non-incendive field wiring practices. Electrical shock can result in death or serious 
injury

• Avoid contact with the leads and terminals. High voltage that may be present on leads 

can cause electrical shock. This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following conditions. This device may not cause harmful 
interference. This device must accept any interference received, including 
interference that may cause undesired operation. This device must be installed to 
ensure a minimum antenna separation distance of 20 cm from all persons.

• The power module may be replaced in a hazardous area. The power module has 

surface resistivity greater than one gigaohm and must be properly installed in the 
wireless device enclosure. Care must be taken during transportation to and from the 
point of installation to prevent electrostatic charge build-up.

IMPORTANT NOTICE

Shipping considerations for wireless products:

The unit was shipped to you without the power module installed. Please remove the 
power module prior to shipping the unit.

Each power module contains two “C” size primary lithium batteries. Primary lithium 
batteries are regulated in transportation by the U.S. Department of Transportation, and 
are also covered by IATA (International Air Transport Association), ICAO (International 
Civil Aviation Organization), and ARD (European Ground Transportation of Dangerous 
Goods). It is the responsibility of the shipper to ensure compliance with these or any other 
local requirements. Please consult current regulations and requirements before shipping.

Emerson Process Management 
Rosemount Division

8200 Market Boulevard
Chanhassen, MN USA 55317
T (US) (800) 999-9307
T (Intnl) (952) 906-8888
F (952) 949-7001

Rosemount Temperature GmbH

Frankenstrasse 21
63791 Karlstein
Germany
T 49 (6188) 992 0
F 49 (6188) 992 112

Emerson Process Management
Asia Pacific Private Limited

1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947 / (65) 6777 0743
[email protected]

Summary of Contents for Rosemount 848T

Page 1: ...0825 0100 4848 Rev AA May 2009 Rosemount 848T Wireless Wireless Considerations Step 1 Physical Installation Step 2 Verify Operation Reference Information Product Certifications EC Declaration of Conformity Start End Rosemount 848T Wireless Temperature Transmitter ...

Page 2: ...ccept any interference received including interference that may cause undesired operation This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons The power module may be replaced in a hazardous area The power module has surface resistivity greater than one gigaohm and must be properly installed in the wireless device enclosure Care must be taken duri...

Page 3: ...his will result in a simpler and faster network installation Enable Active Advertising on the Gateway to ensure that new devices join the network faster For more information see the Smart Wireless Gateway Manual Doc No 00809 0200 4420 Antenna Position The antenna should be positioned vertically and it should be approximately 3 ft 1 m from any large structure building or conductive surface to allow...

Page 4: ...00 4848 Rev AA May 2009 Rosemount 848T Wireless 4 375 Field Communicator Connections The Power Module needs to be connected for the 375 Field Communicator to interface with the 848T Wireless Figure 3 Connection Diagram Maintenance Port ...

Page 5: ...d in the wireless device by using the following Fast Key sequence Sensor Configuration Sensor inputs can be configured for different sensor types To verify or change the sensor configuration with a 375 handheld communicator use the following Fast Key sequence Remote Mount The Rosemount 848T Wireless can only be installed in the Remote Mount configuration where the sensor is mounted separate from t...

Page 6: ...it if necessary from the sensor to the 848T For an easier installation use the outside conduit entries as shown below Any unused conduit entries should be sealed with approved sealant using the included threaded conduit plugs 4 Pull the wiring through the threaded conduit entry of the 848T 5 Attach the sensor wiring to the terminals as indicated on the wiring diagram Note that Terminal screw 5 is ...

Page 7: ...nfigurator 375 Field Communicator For HART communication a 848T Wireless DD is required For connecting with a 375 Field Communicator refer to Figure 3 Connection Diagram on page 4 Smart Wireless Gateway In the Gateway s integrated web interface navigate to the Explorer page This page shows whether the device has joined the network and if it is communicating properly NOTE It may take several minute...

Page 8: ...00825 0100 4848 Rev AA May 2009 Rosemount 848T Wireless 8 Figure 4 Smart Wireless Gateway Explorer Page AMS Wireless Configurator When the device has joined the network it will appear in the Device Manager as illustrated below ...

Page 9: ... Message Date Model Number SI Unit Control Country Device ID Guided Setup 2 1 Join Device to Network Configure Update Rate Configure Sensor Calibrate Sensors Configure Alerts Manual Setup 2 2 Wireless Sensor 1 Sensor 2 Sensor 3 Sensor 4 Device Temperature Device Information Other Wireless 2 2 1 Network ID Join Device to Network Configure Update Rate Configure Broadcast Power Level Power Mode Power...

Page 10: ...ries 183 Thermocouple Lead Wire Configurations Figure 8 Series 185 Thermocouple Lead Wire Configurations NOTE The wiring diagrams shown above apply only to Rosemount sensors Single Element Type J Type E Type K Type T Type J Type N Type K Red 4 Red 3 White 2 White 1 White 2 Red 3 Purple 2 Red 3 Yellow 2 Red 3 Blue 2 Red 3 Black 2 White 3 Red 2 White 3 Green 2 White 3 ...

Page 11: ...ation to ensure that they adhere to regulations regarding the use of the RF spectrum Nearly every country requires this type of product certification Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage FCC and IC This device complies with Part 15 of the FCC Rule...

Page 12: ...A B C and D Dust Ignition proof for Class II III Division 1 Groups E F and G Ambient Temperature Limits 50 to 85 C Non incendive when installed in accordance with Rosemount drawing 00849 1000 For use with Rosemount power module P N 753 9220 0001 only Enclosure Type 4X IP66 Canadian Standards Association CSA I6 CSA Intrinsic Safety Intrinsically Safe for Class I Division 1 Groups A B C and D Temp C...

Page 13: ...up it must not be rubbed or cleaned with solvents or a dry cloth 1180 IECEx Certifications I7 IECEx Intrinsic Safety Certificate No IECEx BAS 09 0004X Ex ia IIC T6 Tamb 60 C to 50 C Ex ia IIC T5 Tamb 60 C to 75 C IP66 For use with Rosemount power module P N 753 9220 0001 only Special Conditions for Safe Use X The surface resistivity of the antenna is greater than one gigaohm To avoid electrostatic...

Page 14: ...tified body certification as shown in the attached schedule Vice President of Global Quality Timothy J Layer 15 January 2009 name printed date of issue function name printed signature c o d A 3 7 0 1 D M R _ X T 8 4 8 3 f o 1 e g a P g n i k r a M E C X T 8 4 8 D I e l i F EC Declaration of Conformity No RMD 1073 Rev A We Rosemount Inc 8200 Market Boulevard Chanhassen MN 55317 6985 USA declare und...

Page 15: ... option code WK All Models with the Extended Range Antenna option code WM n o i t c i r t s e R y r t n u o C Bulgaria General authorization required for outdoor use and public service France Outdoor use limited to 10mW e i r p Italy If used ourside of own primises general authorization is required Norway May be restricted in the geographical area within a radius of 20km from the center of Ny Ales...

Page 16: ... a M E C X T 8 4 8 D I e l i F Notified Bodies for EC Type Examination Certificate Baseefa Notified Body Number 1180 Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom ATEX Notified Body for Quality Assurance Baseefa Notified Body Number 1180 Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom ...

Page 17: ...Quick Installation Guide 00825 0100 4848 Rev AA May 2009 Rosemount 848T Wireless 17 ...

Page 18: ...Quick Installation Guide 00825 0100 4848 Rev AA May 2009 Rosemount 848T Wireless 18 ...

Page 19: ...Quick Installation Guide 00825 0100 4848 Rev AA May 2009 Rosemount 848T Wireless 19 ...

Page 20: ...Quick Installation Guide 00825 0100 4848 Rev AA May 2009 Rosemount 848T Wireless 20 ...

Reviews: