background image

10

Rosemount 65Q

September 2014

www.rosemount.com

Specifications

Material selection

Emerson provides a variety of Rosemount product with various 
product options and configurations including materials of 
construction that can be expected to perform well in a wide 
range of applications. The Rosemount product information 
presented is intended as a guide for the purchaser to make an 
appropriate selection for the application. It is the purchaser’s 
sole responsibility to make a careful analysis of all process 
parameters (such as all chemical components, temperature, 
pressure, flow rate, abrasives, contaminants, etc.), when 
specifying product, materials, options and components for the 
particular application. Emerson Process Management is not in a 
position to evaluate or guarantee the compatibility of the 
process fluid or other process parameters with the product, 
options, configuration or materials of construction selected.

Nominal resistance

In accordance with DIN EN 60751, the nominal resistance is 
defined as follows:

100 

Ω

 RTD at 0 °C

Temperature coefficient 

α

 = 0.00385 

Ω

 x °C/

Ω

), averaged 

between 0 and 100 °C

Limit deviations

Tolerance Class A as standard: t = ± (0.15 + 0.002 x t); 
valid for the temperature range from 0 to +350 °C

Lead wire configuration

As single element (1Pt 100) with 3 or 4 lead wires or dual 
element (2Pt 100) with 3 lead wires

Response time

Less than 12 seconds to reach 63% step change in water flowing 
at 0.4 m/s

Process temperature range

-50 to +450 °C
The measurement range can be limited by the gasket in the 
process connection.

Ambient temperature 

Housing without head-mounted transmitter

Metal housings: -40 to +130 °C

Plastic housings: -40 to +85 °C

Housing with head-mounted transmitter

 -40 to +85 °C

Maximum process pressure

Lower maximum pressure can be due to the process connection
Pressure ratings at 20 °C:

Tri-Clamp: 10 bar

Weld-in Ball with PEEK-Seal: 6 bar

Weld-in Ball with SST-Seal: 40 bar

Threaded: 40 bar

Tapered Union with Coupling Nut: 10 bar

VARIVENT: 10 bar

Shock and vibration resistance

According to DIN EN 60751: 2.8 g peak / 10…500 Hz

Self heating

0.15 °K/mW when measured per method defined in DIN EN 
60751

Insulation resistance

1,000 M

Ω

 minimum insulation resistance when measured at 

500 Vdc and at room temperature

Sheath material

321 Stainless Steel with mineral-insulated cable construction

Lead wire

PTFE insulated, silver coated copper wire

Summary of Contents for Rosemount 65Q

Page 1: ...stries Aseptic process connections suitable for CIP and SIP dead pocket free measurement applications Exchangeable measuring insert to ensure process integrity Enhanced system accuracy with transmitter sensor matching meets pharmaceutical industry requirements Resistance Temperature Sensors for Hygienic and Sanitary Applications P r o d u c t D i s c o n t i n u e d ...

Page 2: ...on points Integral thermowell protection on 65Q allows for ordering sanitary sensor and thermowell together Explore the benefits of a Complete Point Solution from Rosemount Temperature Measurement An Assemble Sensor to Specific Transmitter option enables Emerson to provide a complete point temperature solution delivering an installation ready transmitter and sensor assembly Emerson has a complete ...

Page 3: ...3 Rosemount 65Q September 2014 www rosemount com Content Rosemount 65Q Sensor 2 Rosemount 65Q Sanitary Sensor 4 Introduction 8 Specifications 10 Dimensional Drawings 16 ...

Page 4: ...andard offering represents the most common options The starred options should be selected for best delivery __The Expanded offering is subject to additional delivery lead time Model Product description 0065Q 65Q RTD Sensor with Twell for Sanitary Applications Connection head IP rating 1 Connection thread C Rosemount Aluminum 68 M20 x 1 5 D Rosemount Aluminum 68 1 2 in NPT 1 Rosemount Aluminum with...

Page 5: ...Mounting Style code T02 0050 50 mm 0065 65 mm 0100 100 mm 0150 150 mm 0200 200 mm 0250 250 mm XXXX Non standard immersion length non standard lengths are available from 25 to 2500 mm Thermowell mounting style Process connection Stem style C02 Flanged 1 in Tri Clamp diameter 50 4 mm Stepped 10 6 mm 4 C04 Flanged 11 2 in Tri Clamp diameter 50 4 mm Stepped 10 6 mm 4 C06 Flanged 2 in Tri Clamp diamete...

Page 6: ...0 6 mm 4 V04 VARIVENT DN 1 1 2 3 inch Dim 68 mm Standard Options include with selected model number Sensor options A3 Single Element Class 1 3 DIN B Sensor 0 to 100 C 32 to 212 F A4 Dual Element Class 1 3 DIN B Sensor 0 to 100 C 32 to 212 F Product certifications I1 EEx ia ATEX IBExU Intrinsic Safety Approval Cable gland option G2 Cable Gland EEx d Brass 7 5 mm 11 9 mm Cover chain option G3 Cover ...

Page 7: ...ll threads must be sealed 2 Standard length for use with Connection Head codes C D 1 and 2 3 Standard length for use with Connection Head codes E F J L R S T 5 and 6 4 For U 50 mm outer diameter 6 mm straight below part of process connection 5 Valid for DIN B connection heads only 6 According to DIN 11851 7 For Up 65 mm the outer diameter is 6 mm for straight stem styles 8 If ordering XA with a tr...

Page 8: ...ther public health authorities around the world While 3 A Sanitary Standards have been in development and use since the late 1920 s EHEDG is a fairly recent development that applies test criteria and laboratory test data for determining cleanability and acceptance for equipment use in the processing of foods or comestibles Both EHEDG and 3 A Sanitary Standards may be applied not only to Food and B...

Page 9: ... leads Code 0 Single element 3 wire Single element 4 wire Dual element 3 wire Series 65 RTD terminal block termination Code 2 Single element 3 wire Single element 4 wire Dual element 3 wire Red Red White Red Red White White Red Red Green Black Blue Blue White Red Red Red Red White White White White Red Red Red Red ...

Page 10: ...aged between 0 and 100 C Limit deviations Tolerance Class A as standard t 0 15 0 002 x t valid for the temperature range from 0 to 350 C Lead wire configuration As single element 1Pt 100 with 3 or 4 lead wires or dual element 2Pt 100 with 3 lead wires Response time Less than 12 seconds to reach 63 step change in water flowing at 0 4 m s Process temperature range 50 to 450 C The measurement range c...

Page 11: ...ons Thermowell surface qualities Ra 0 8 μm as standard electropolishing Ra 0 4 μm optional electropolishing Connection heads see Table 2 The connection heads can be of different types size DIN A and B and materials plastic aluminum stainless steel Its fitting to the rest of the probe and the gland for the cable entry assure an IP grade of 65 at minimum All supplied heads have a process connection ...

Page 12: ...ded DIN plate 644 248 M20 x 1 5 1 2 in NPT Yes Polished DIN B SST 66 Threaded DIN plate 248 M20 x 1 5 1 2 in NPT No Rosemount Aluminum 68 Threaded DIN plate 644 248 M20 x 1 5 1 2 in NPT Yes TZ A BK Polyamide 65 Screw on cap On cover terminal block 644 248 M20 x 1 5 No TZ A BL Aluminum 65 Screw on camp On cover terminal block 644 248 M20 x 1 5 No GR A BL Aluminum 65 Screw on camp DIN plate 644 248 ...

Page 13: ...f piping allow in line temperature measurement by the use of counter part and suitable seal O ring on customer site Meet the 3 A Sanitary Standard Meets ASME BPE 2002 standards Tapered union with coupling nut according to DIN 11851 dairy connection Immersion lengths from 25 to 500 mm Available in DN10 DN50 tube OD sizes larger sizes than 50 DN are available upon request Available in material 1 440...

Page 14: ...Available in material 1 4404 316L Used for temperature measurement in non hygienic processes VARIVENT process connection Immersion lengths from 35 to 500 mm Available in D 68 mm Suitable for hygienic and aseptic applications PARALLEL 26 NP UP T T1 TAPERED 26 NT UT T T1 26 N T D U D Process Connection Diameter T Thermowell Outer Diameter U Immersion Length N Extension Length Dimensions mm T T1 6 1 ...

Page 15: ...o 120 mm In pipes with smaller diameter the axis line of the duct must be reached and even slightly exceeded by the sensor tip In hygienic applications a strict installation rule exists so as not to leave any dead spaces along the run of process fluid In case of disassembling of the sensor new gaskets equal to the originals and specific torques must be employed for the reassembly procedure to assu...

Page 16: ...nnection Heads Rosemount Aluminum Codes C D 1 2 DIN A SST Codes E F 5 6 DIN B Polished SST Codes R S TZ A BL Aluminum Code L FR A BL Aluminum Code J TZ A BK Polyamide Code T 40 25 25 25 25 25 Sensor Lead Wire Terminations Flying leads Code 0 Terminal block Code 2 3 2 L L 3 2 ...

Page 17: ...ww rosemount com All dimensions are in millimeters Thermowells and Process Connections Tri Clamp Weld in ball adjustable Tapered union with coupling nut Threaded tapered Threaded parallel Stepped thermowell Straight thermowell VARIVENT ...

Page 18: ...rket Boulevard Chanhassen MN 55317 USA T U S 1 800 999 9307 T International 952 906 8888 F 952 906 8889 www rosemount com Emerson Process Management Blegistrasse 23 P O Box 1046 CH 6341 Baar Switzerland T 41 0 41 768 6111 F 41 0 41 768 6300 www rosemount com Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Signapore 128461 T 65 6777 8211 F 65 6777 0947 Service Support Hotline 65 6...

Reviews: