100
250V AC
~
50/60 HZ
4VA
3
4
5
1
2
~
L
N
SSR
+
-
7
6
-
7
6
8
9
10
11
12
+
-
T/C
NC
C
R1
NO
www.multispanindia.com
Page - 1
TC-49
2)
If Sensor is not Connected, Display will show “
OPN
” message.
3) To Show set point, press Key.
Note:
4) Auto out time is 15 sec without saving.
5) Every time the instument is turn on,following pattern will be displayed.
Technical Specification
Technical Specification
POWER ON
Display for 3 sec
display for 2 sec, according to the input
sensor programmed.
display for 2 sec, according to the control
action programmed.
Process Value
8 8
8
t c J
T P
3 0
3 Digit 7 seg 0.56”,red LED Display
J type: 0 to 600°C
K type: 0 to 999°C
TP/ ON-OFF (selectable)
Output
Power Supply
Operating
Temperature
Relative
Humidity
100 to 250V AC,50/60 Hz, Approx 4VA
0°C To 55°C
Up to 95% RH Non Condensing
Model
Display
Size (mm)
Panel Cutout
Input
Temperature
Range
Control Action
48 (H) X 48 (W) X 70 (D) mm
44 X 44 mm
TC-49
J TYPE/ K TYPE
1Relay, 1C/O Contact,10A, 230V AC
S.S.R, 12V DC approx, 10mA DC.
SET
SET
Connection Diagram
OPERATING MANUAL
TEMPERATURE CONTROLLER
TC-49
1 2 3
Protection
Level
(As per request)
IP-65 (Front side) As per IS/IEC 60529 : 2001
1)
If Sensor Connection is reverse, Display will show “
SRE
” message.
°C
TC 49