Table 4-1.
Profile options for flow
Hmax
Scale Factor
Power
Factor
20 mA Point
(1)
Options
Flow Structures
Metric
(m)
Imperial
(ft/in.)
Metric
(m
3
/hour)
Imperial
(GPM
(2)
)
Metric
(m)
Imperial
(ft/in.)
3/2
Flume 3/2 flow law
-
(User)
(User)
1.5
(User)
(User)
5/2
V-Notch 5/2 flow law
-
(User)
(User)
2.5
(User)
(User)
mann
Manning formula
-
(User)
(User)
(User)
-
-
PAr01
1 inch Parshall flume
0.75
2.5
217.3
151.7
1.55
17.9
87.3
PAr02
2 inch Parshall flume
0.75
2.5
434.6
303.4
1.55
50.7
215
PAr03
3 inch Parshall flume
0.75
2.5
635.5
445.2
1.547
125
516
PAr06
6 inch Parshall flume
0.75
2.5
1372
924.5
1.58
389
1750
PAr09
9 inch Parshall flume
0.75
2.5
1927
1378
1.53
882
3980
PAr1
1 ft Parshall flume
0.75
2.5
2487
1795
1.522
1610
7240
PAr1.5
1
1
/
2
ft Parshall flume
0.75
2.5
3803
2693
1.538
2440
11000
PAr2
2 ft Parshall flume
0.75
2.5
5143
3590
1.550
3290
14900
PAr3
3 ft Parshall flume
0.75
2.5
7863
5386
1.566
5010
22600
PAr4
4 ft Parshall flume
0.75
2.5
10630
7181
1.578
6750
30500
PAr5
5 ft Parshall flume
0.75
2.5
13440
8976
1.587
8510
38400
PAr6
6 ft Parshall flume
0.75
2.5
16280
10770
1.595
10300
46400
PAr8
8 ft Parshall flume
0.75
2.5
22010
14360
1.607
13900
62600
PAr10
10 ft Parshall flume
0.75
2.5
84256
17672
1.6
20700
89200
FF01
(3)
Flume Flat 1 (m)
0.102
134.7877
1.5
9
FF02
(3)
Flume Flat 2 (m)
0.191
178.2664
1.5
36
FF03
(3)
Flume Flat 3 (m)
0.267
313.4177
1.5
90
FF04
(3)
Flume Flat 4 (m)
0.406
541.7157
1.5
360
FF05
(3)
Flume Flat 5 (m)
0.635
811.1058
1.5
900
FF06
(3)
Flume Flat I
0.200
132.2
1.5
30
FF07
(3)
Flume Flat II
0.250
177.7
1.5
60
FF08
(3)
Flume Flat III
0.300
217.58
1.5
90
FF09
(3)
Flume Flat III bis
0.3333
328.35
1.5
200
FF10
(3)
Flume Flat III ter
0.400
272.0
1.5
200
FF11
(3)
Flume Flat IV
0.400
352.1726
1.5
180
FF12
(3)
Flume Flat V
0.500
442.932
1.5
360
FF13
(3)
Flume Flat V bis
0.400
400.5
1.5
320
FF14
(3)
Flume Flat VI
0.540
499.0569
1.5
720
FF15
(3)
Flume Flat VII
0.700
623.7
1.5
1080
FF16
(3)
Flume Flat VIII
0.600
881.16
1.5
1440
FF17
(3)
Flume Flat VIII bis
0.666
798.0
1.5
1500
FF18
(3)
Flume Flat IX
0.800
1065.186
1.5
1800
FF19
(3)
Flume Flat IX bis
0.733
814.8
1.5
1700
FF20
(3)
Flume Flat X
0.867
1322.2761
1.5
3600
FF21
(3)
Flume Flat X bis
1.200
1609.0
1.5
7500
FF22
(3)
Flume Flat X ter
0.959
1064.884
1.5
3500
FF2 3
(3)
Flume Flat XI
1.200
1650.99
1.5
7200
FP01
(3)
Flume Parabolic 1
0.200
15878.5
2.3
20
FP02
(3)
Flume Parabolic 2
0.250
17591.1
2.3
40
FP03
(3)
Flume Parabolic 3
0.310
11645.6
2.2
90
FP04
(3)
Flume Parabolic 4
0.380
13669.5
2.2
180
FP05
(3)
Flume Parabolic 5
0.460
9802.7
2.1
360
FP06
(3)
Flume Parabolic 6
0.600
11367.8
2.1
720
FP07
(3)
Flume Parabolic 7
0.800
12227.7
2.1
1400
(1) Upper range value if set to AUTO. Lower range value (4 mA) is set to 0.
(2) The gallons are US gallons.
(3) Flume option not available if base units are imperial.
Summary of Contents for Rosemount 3100 Series
Page 2: ......
Page 4: ......
Page 12: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series 1 4 ...
Page 16: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series 2 4 ...
Page 84: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series A 10 ...
Page 97: ...Reference Manual 00809 0100 4840 Rev BA July 2008 B 13 Rosemount 3100 Series Sheet 2 of 3 ...
Page 98: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series B 14 Sheet 3 of 3 ...
Page 104: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series C 6 ...
Page 114: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series E 6 ...
Page 140: ...Reference Manual 00809 0100 4840 Rev BA July 2008 Rosemount 3100 Series F 26 ...
Page 141: ......
Page 142: ......
Page 143: ......