Quick Start Guide
3
June 2016
1.0 Mount the transmitter
1.1 Installing the Rosemount 3095FC on a pipestand
The following steps must be taken to install the Rosemount 3095FC on a 2-in.
pipestand:
1. Install the pipestand using the pipestand documentation.
2. Remove the orifice/meter run from service.
3. Install the Rosemount 3095FC on a pipestand using clamps or mounting
brackets.
4. Connect the impulse lines.
1.2 Installing the Rosemount 3095FC on an orifice plate (direct
mount)
The following steps must be taken to install the Rosemount 3095FC on an orifice
plate:
1. Remove the orifice/meter run from service.
2. Install the Rosemount 3095FC on the meter run using a manifold and
hardware to secure the Rosemount 3095FC to the orifice flanges.
Figure 1. Gas Flow Application
4832 Rev CA.fm Page 3 Wednesday, June 22, 2016 2:06 PM