7.0 Product Certifications

7.1 Approved Manufacturing Locations

Rosemount Inc. — Chanhassen, Minnesota  USA

7.2 European Directive Information

The EC declaration of conformity for all applicable European directives for this product can 
be found on the Rosemount website at 

EmersonProcess.com/Rosemount

. A hard copy may 

be obtained by contacting our local sales office.

ATEX Directive (94/9/EC)

Emerson Process Management complies with the ATEX Directive.

European Pressure Equipment Directive (PED) (97/23/EC)

Rosemount 3095F_2/3,4/D Flow Transmitters 

— QS Certificate of Assessment - EC No. PED-H-100 Module H Conformity Assessment

All other 3095_ Transmitters/Level Controller 

— Sound Engineering Practice

Transmitter Attachments: Process Flange - Manifold 

— Sound Engineering Practice

Electro Magnetic Compatibility (EMC) (2004/108/EC)

Rosemount 3095F Flow Transmitters - EN 61326-1:1997 - A1, A2, and A3

Ordinary Location Certification for Factory Mutual

As standard, the Rosemount 3095FB Transmitter has been examined and tested to 
determine that the design meets basic electrical, mechanical, and fire protection 
requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the 
Federal Occupational Safety and Health Administration (OSHA).

7.3 Hazardous Locations Certifications

North American Certifications

Canadian Standards Association (CSA) - U.S. and Canada

M

Explosion-Proof for Class I, Division 1, Groups C and D including optional solar panel: 

mast option: Suitable for use in Class I, Division 2, Groups A, B, C, D, and T3. CSA 
Enclosure Type 4.

European Certifications

H

ATEX Flame4proof 

Certificate: LCIE05ATEX6057X 

 II 2 G

EEx d IIB T5 
V

max

 = 28V dc

IP66

 1180

Special Conditions for Safe Use (x):

1. Operating ambient temperature: –40 °C to 75 °C.
2. The users have to make sure that the thermal fluid transfer doesn’t overheat the 

equipment to a temperature corresponding to the spontaneous combustion 
temperature of surrounding gas.

4832 Rev CA.fm  Page 11  Wednesday, June 22, 2016  2:06 PM

Summary of Contents for Rosemount 3095FC MultiVariable

Page 1: ...Quick Start Guide 00825 0100 4832 Rev CA June 2016 with Modbus Protocol Rosemount 3095FC MultiVariable Mass Flow Transmitter ...

Page 2: ... and practices Before connecting communications in an explosive atmosphere make sure the instruments in the loop are installed in accordance with intrinsically safe or non incendive field wiring practices In an Explosion Proof Flame Proof installation do not remove the transmitter covers when power is applied to the unit Process leaks may cause harm or result in death To avoid process leaks only u...

Page 3: ... from service 3 Install the Rosemount 3095FC on a pipestand using clamps or mounting brackets 4 Connect the impulse lines 1 2 Installing the Rosemount 3095FC on an orifice plate direct mount The following steps must be taken to install the Rosemount 3095FC on an orifice plate 1 Remove the orifice meter run from service 2 Install the Rosemount 3095FC on the meter run using a manifold and hardware t...

Page 4: ...pically carbon steel or stainless steel Confirm the material by viewing the markings on the head of the bolt and referencing Table 1 If bolt material is not shown in Table 1 contact the local Emerson Process Management representative for more information Use the following bolt installation procedure 1 Carbon steel bolts do not require lubrication and the stainless steel bolts are coated with a lub...

Page 5: ...ury The two flange adapters are distinguished by unique O ring grooves Only use the O ring that is designed for its specific flange adapter as shown below A Flange adapter B O ring C PFTE D Elastomer Whenever the flanges or adapters are removed visually inspect the o rings Replace them if there are any signs of damage such as nicks or cuts If you replace the o rings re torque the flange bolts and ...

Page 6: ... signal errors Table 2 displays the RTD terminal connections for the various RTD probes 3 Wire the power supply The terminals are labeled CHG for positive power connection and CHG for negative power connection on a label on the termination board These connections provide the input voltage and power for the battery charging circuit The maximum voltage that can be applied to the CHG CHG terminals is...

Page 7: ...al communications port on the PC The other end of the cable plugs into the Rosemount 3095FC Figure 3 Operator Interface Wiring Table 3 Local Operator Interface Port Wiring Signal Label Common COM LOI Power 1 1 Do not use the LOI to power external devices TX V Common COM Ready to Send RTS Receive RX Transmit TX 1 6 7 8 9 2 3 4 5 To screw terminals Connection at PC COM port White TX Red TX Black TX ...

Page 8: ...ace the power jumper in the ON position The jumper is located on the LCD display if installed or at J1 on the Battery Charger Board 4 Screw the front end cap cover LCD display end After the Rosemount 3095FC completes start up diagnostics RAM and other internal checks the optional LCD display shows the date and time to indicate that the Rosemount 3095FC completed a valid reset sequence A LOI B RET ...

Page 9: ...e Gas Quality tab from the top of the screen and verify the correct gas composition for your process 9 Select the Advanced tab from the top of the screen Verify the correct values for FPV method units of measure and all geographical parameters Select OK to exit the screen 6 0 Trim the transmitter Note Transmitters are shipped from Emerson Process Management Emerson fully calibrated per request or ...

Page 10: ... window 4 Verify Reading to determine if a Zero Sift correction is required 5 If the reading is not zero select Set Zero Shift to adjust the Zero and select Done If the reading is zero select Done 6 Select Done to close the calibration window and cancel the freeze values to begin using live readings for the flow calculations 7 Once the zero trim is complete verify that the high side block valve is...

Page 11: ...mitters EN 61326 1 1997 A1 A2 and A3 Ordinary Location Certification for Factory Mutual As standard the Rosemount 3095FB Transmitter has been examined and tested to determine that the design meets basic electrical mechanical and fire protection requirements by FM a nationally recognized testing laboratory NRTL as accredited by the Federal Occupational Safety and Health Administration OSHA 7 3 Haza...

Page 12: ...June 2016 12 Quick Start Guide Figure 5 Rosemount 3095FC Declaration of Conformity ...

Page 13: ...Quick Start Guide 13 June 2016 ...

Page 14: ...June 2016 14 Quick Start Guide ...

Page 15: ...Quick Start Guide 15 June 2016 ...

Page 16: ...y X O O O O O ༣փ㓴Ԧ Housing Assembly X O O X O O Րᝏಘ㓴Ԧ Sensor Assembly X O O X O O ᵜ㺘Ṭ ᦞ SJ T11364Ⲵ㿴ᇊ㘼ࡦ This table is proposed in accordance with the provision of SJ T11364 O Ѫ䈕䜘ԦⲴᡰᴹ 䍘ᶀᯉѝ䈕ᴹᇣ 䍘Ⲵਜ਼䟿 վҾGB T 26572ᡰ㿴ᇊⲴ䲀䟿㾱 O Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Ѫ 䈕䜘Ԧᡰ Ⲵᡰᴹ 䍘ᶀᯉ䟼ˈ㠣ቁᴹа 䍘ᶀᯉѝ䈕ᴹᇣ 䍘Ⲵਜ਼䟿儈ҾGB T 26572ᡰ㿴...

Page 17: ...Quick Start Guide 17 June 2016 ...

Page 18: ...es Terms of Use aspx The Emerson logo is a trademark and service mark of Emerson Electric Co MultiVariable Rosemount and Rosemount logotype are trademarks of Emerson Process Management Modbus is a registered trademark of Gould Inc All other marks are the property of their respective owners 2016 Emerson Process Management All rights reserved Europe Regional Office Emerson Process Management Europe ...

Reviews: