Quick Installation Guide
00825-0100-4801, Rev HA
February 2008
Rosemount 3051S
9
S
TEP
4
CONTINUED
...
Intrinsic Safety Consideration:
The transmitter assembly with
remote display has been approved with Belden 3084A DeviceNet
cable. Alternate cable may be used as long as the transmitter with
remote display and cable is configured according to the installation
control drawing or certificate. Refer to appropriate approval certificate
or control drawing in Appendix B of the 3051S reference manual for
remote cable IS requirements.
IMPORTANT
Do not apply power to the remote communications terminal. Follow
wiring instructions carefully to prevent damage to system components.
Figure 4. Remote Mount Display wiring diagram
Junction Box Housing
Remote Mount Display
4-20 mA
(white) 24 AWG
(blue) 24 AWG
(black) 22 AWG
(red) 22 AWG
4801_QIG_RevHA.fm Page 9 Tuesday, February 26, 2008 12:17 PM