Note
The Rosemount 148 must be configured before installation.
This can be done in one of two ways:
•
Ordering factory configuration by Emerson
•
Using the Rosemount 148 PC Programmer interface in a bench configuration setting
3.3.1
Software installation
Procedure
1. Place the Rosemount
™
148 PC Programmer CD_ROM into the drive.
2. Run setup.exe from Windows
™
XP, 7, 8, or 10.
3. When first using the software, configure the appropriate COM ports by selecting
Port Settings
from the
Communicate
menu.
4. Install MACTek
®
Modem drivers completely before beginning bench configuration
on the Rosemount 148 system.
Note
The software defaults to the first available COM port.
3.3.2
Rosemount 148 programming
Table 3-1: Programming Kit Spare Part Numbers
Product description
Part number
Programming software (CD)
00148-1601-0002
Rosemount 148 programmer kit — USB
00148-1601-0003
Rosemount 148 programmer kit — serial
00148-1601-0004
3.3.3
PC Programmer hardware setup
The Rosemount
™
148 PC Programming Kit includes configuration software and a
communication modem. The Rosemount 148 device will need an external power supply of
12–42.4 Vdc for configuration.
Procedure
1. Hook up the transmitter and a load resistor (250–1100 Ω) wired in series with the
power supply.
2. Attach the modem in parallel with the load resistor and connect it to the PC.
Postrequisites
for spare kit and re-order numbers.
Configuration
Reference Manual
June 2019
00809-0100-4148
26
www.Emerson.com
Summary of Contents for Rosemount 148
Page 1: ...Reference Manual 00809 0100 4148 Rev DA June 2019 Rosemount 148 Temperature Transmitter ...
Page 4: ...Contents Reference Manual June 2019 00809 0100 4148 iv www Emerson com ...
Page 10: ...Introduction Reference Manual June 2019 00809 0100 4148 10 www Emerson com ...
Page 24: ...Installation Reference Manual June 2019 00809 0100 4148 24 www Emerson com ...
Page 34: ...Operation and Maintenance Reference Manual June 2019 00809 0100 4148 34 www Emerson com ...