background image

Part No. F40BP73380000

Form No. BP7338

U.L. Model No.: CF2605/CF2680

READ AND SAVE THESE INSTRUCTIONS

Raphael Model No.

CF2605PW00

CF2605WB00

Raphael Tiffany Model No.

CF2680WB00 

RAPHAEL

RAPHAEL

TIFFANY

Net Weight:  

29.5 

Lbs.

52” Ceiling Fan
Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling fan against all defects in workmanship and
materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for a lifetime from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of
the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Electric Co. will refund the actual
purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL
COSTS OF REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.

How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of

Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON ELECTRIC CO. IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to
such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which
was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Summary of Contents for RAPHAEL CF2605PW00

Page 1: ... your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for an...

Page 2: ... outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The longer downrod 18 furnished with the ceiling fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling The 4 1 2 downrod supplied must be used for an 8 foot ceiling 5 The fan must be mounted with the ...

Page 3: ...ill insure that all steps have been completed and will be helpful in finding your place should you be interrupted BLADE FLANGES ROD SUPPORT ASSEMBLY HANGER BALL DOWNROD ASSEMBLY YELLOW UPLIGHT LEAD ASSEMBLY FAN MOTOR HOUSING AND SHADE ASSEMBLY SW105 RECEIVER REVERSING MODULE SW116 FAN LIGHT WALL CONTROL CEILING COVER LOOSE PARTS BAG HANGER BRACKET MOTOR COVER GLASS SHADE LIGHT KIT ADAPTER ASSEMBLY...

Page 4: ...ircuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a q...

Page 5: ...w securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING 9 Position the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 4 10 Reinstall the hanger ball on the downrod as follows Route the motor leads through the hanger ball and slide the hanger ball over the downrod...

Page 6: ...aced Consult a qualified electrician if in doubt WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TAB OUTLET BOX Figure 7 TOP OF HOUSING CANDELABRA BASE LAMP SOCKET Figure ...

Page 7: ...sk of electrical shock disconnect the electrical supply circuit before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 9 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the...

Page 8: ...e the outlet box and not pinched between the ceiling cover and the ceiling WARNING DOWNROD WHITE SUPPLY WIRE BLACK FAN WIRE SW105 RECEIVER TO 110V SUPPLY YELLOW RECEIVER WIRE WHITE FAN WIRE BLUE RECEIVER WIRE BLUE FAN WIRE BLACK SUPPLY WIRE WHITE RECEIVER WIRE BLACK RECEIVER WIRE BLACK WHITE RECEIVER WIRE YELLOW FAN WIRE Check to see that all connections are tight including ground and that no bare...

Page 9: ...lation 4 Using the 5 64 hex wrench supplied loosen the setscrew in the collar on the light kit adapter assembly Then pass the connector and the wires from the motor shaft through the collar Figure 15 Screw the adapter assembly onto the motor shaft and then tighten the setscrew to secure the adapter assembly to the motor shaft 5 Engage the connector from the motor shaft with the connector from the ...

Page 10: ...ur ceiling fan is now installed and wired and ready for use Setting Operating Frequency of Wall Control and Receiver Figure 18 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in th...

Page 11: ...your needs and snap the cover onto the wall control Figure 19 12V BATTERY WALL CONTROL COVER SW116 WALL CONTROL HI HI MED MED LOW LOW FAN OFF REV REV EMERSON D L D L U L U L Figure 19 Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box WARNING Battery Installation of Wall Control 3 Install the wall c...

Page 12: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to radio communications However there is not guarantee that interference will not occur in a particular installatio...

Page 13: ...ssembly and loosely engage the rod hook with one of the rings on the support assembly Figure 24 Then tighten the setscrew using the 5 64 hex wrench supplied 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 25 Then securely tighten the setscrew using the 5 64 hex...

Page 14: ...es not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to Step 12 in the Assembly Instructions 5 Hanger bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box securely fastened and or secure outlet box 6 Fan bl...

Page 15: ... 17 24 Screw 8 Washer head 4 25 Capacitor 9 mfd 762117 762117 762117 26 Motor 762508 762508 762508 27 Hub Motor 760601 760601 760601 28 Flange Set Full set for one fan 762105 1 762105 2 762105 1 29 Adapter Assembly Light Kit 762094 762094 762094 30 Plate Assembly Light Kit 762905 762905 762905 31 Glass Shade Lower 762096 762096 762472 32 Glass Shade Upper 762097 762097 762471 33 Downrod 18 760239 ...

Page 16: ...100 W Florissant St Louis MO 63136 Printed in China 10 07 Part No F40BP73380000 Form No BP7338 11 26 13 HI MED LOW FAN OFF REV EMERSON D L U L 5 27 12 23 8 7 24 28 17 21 14 15 29 30 31 18 19 22 16 8 7 34 1 2 3 6 4 10 9 35 33 25 36 37 38 32 20 Repair Parts ...

Reviews: