7. Wall Control Installation
The Fan Speed Control is designed to operate only ONE
Ceiling Fan, and NOT an Accessory Light Kit. This Wall
Control is Rated for 1.2 Amps at 120 Volts. To avoid
erratic speeds and possible damage to your Ceiling Fan,
use this Control ONLY with the Fan Pull Chain Switch set
to its High Speed Setting.
NOTE: The “0” position is OFF. The four fan speeds
are selected by sliding the bar to the other four speed
positions (“1”, “2”, “3” and “4”).
1.
Before Disconnecting Power, ensure that the Fan is set
at the Highest Speed.
NOTE: Electric connections should be in accordance
with the National Electrical Codes and all Local
Codes. Before starting, disconnect power to the
circuit at the fuse box or circuit breaker panel.
2.
Remove the Faceplate and Screws from the existing
Wall Switch. Pull Switch out from Wall Outlet Box.
3.
Disconnect Wires from Existing Fan Wall Switch
(Figure 19).
4.
Slide the Fan Control in the OFF position (0).
5.
Connect one Fan Speed Control BLACK Wire to the
Fan/Motor Lead with a Wire Connector (supplied)
(Figure 20).
6.
Connect the other Fan Speed Control BLACK wire to
the 120VAC Hot Wire with a Wire Connector (supplied)
(Figure 20).
NOTE: Use wire connectors (supplied) to secure
electrical connections.
7.
Attach the Fan Speed Control to the Wall Outlet Box
with Two 6-32 x 3/4” Screws (supplied).
8.
Position the Faceplate (supplied) onto the Speed
Control. Using the Two 6-32 x 1/4” Screws, screw the
Faceplate and Speed Control to the Wall Outlet Box
(Figure 21).
9.
Restore Power at the Main Fuse Box or Circuit Breaker
Panel.
FACEPLATE
SWITCH
WALL
OUTLET
BOX
Figure 19
MOTOR LOAD
1.2 AMP MAXIMUM
TO 120VAC
SOURCE HOT
BLACK
BLACK
4
0
3
2
1
TO
NEUTRAL
TO FAN MOTOR LOAD
Figure 20
6-32 x 1/4"
SCREWS (2)
FACEPLATE
FAN
CONTROL
OUTLET
BOX
4
0
3
2
1
6-32 x 3/4"
SCREWS (2)