background image

Part No. F40BP74800000

Form No. BP7480

Revision: 131218

U.L. Model No.: CF5100

READ AND SAVE THESE INSTRUCTIONS

PENBROOKE SELECT

Ceiling Fan Owner's Manual

CF5100BS00 - 

Brushed Steel

CF5100GES00 - 

Golden Espresso

CF5100ORB00 - 

Oil Rubbed Bronze

CF5100SW00 - 

Satin White

CF5100VNB00 - 

Venetian Bronze

CF5100VS00 - 

Vintage Steel

Model Numbers

Net Weight: 

20.2

Lbs.

Questions, problems, missing parts: Before returning to the store call

Emerson Electric Customer Service 

8 a.m. - 6 p.m., Eastern, Monday-Friday

1-800-654-3545

www.emersonfans.com

44”, 54”, or 60” Fan Blades

Not Included

(B79 Not Recommended)

BP7480 CF5100 PENBROOKE SELECT  12/18/13  10:35 AM  Page 1

Summary of Contents for PENBROOKE SELECT CF5100BS00

Page 1: ...00 Oil Rubbed Bronze CF5100SW00 Satin White CF5100VNB00 Venetian Bronze CF5100VS00 Vintage Steel Model Numbers Net Weight 20 2 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com 44 54 or 60 Fan Blades Not Included B79 Not Recommended BP7480 CF5100 PENBROOKE SELECT 12 18 13 10...

Page 2: ...d by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of par...

Page 3: ...ove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly 1 3 Remove the fan motor assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the bottom of the motor facing up The upper foam pad serves as a holder for the fan during assembly B D C H I A F E G PACKAGE CONTENTS Part Description Quantity A Fan Motor Hou...

Page 4: ...let box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at t...

Page 5: ...e The blade flanges have an interlocking feature that must be fully engaged before tightening the screw Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again NOTE Take care not to scratch fan housing assembly when...

Page 6: ...OT SWITCH CUP ASSEMBLY SWITCH CUP ADAPTER Figure 4 Installation of Switch Cup Assembly for Manual Control 3 5 Carefully tuck all wires and connectors under the switch cup assembly Secure the switch cup assembly by installing the three 6 32 x 3 8 flat head screws provided Figure 5 SWITCH CUP ASSEMBLY 6 32 x 3 8 FLAT HEAD SCREWS 3 Figure 5 3 6 Turn the partially assembled ceiling fan right side up f...

Page 7: ...the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed DOWNROD PIN SETSCREW HANGER BALL Figure 7 3 7 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 7 Remove the pin from the down...

Page 8: ...SETSCREW CEILING COVER 3 12 Pass the 80 inch long motor leads through the opening in the ceiling cover Be sure the cover is oriented as shown Figure 12 3 13 Reinstall the hanger ball Figure 12 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball...

Page 9: ...lectrician if in doubt WARNING CEILING FLOOR AT LEAST 7 Figure 13 4 How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 13 WARNING 4 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 14 4 2 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figur...

Page 10: ... grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard WARNING NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY OU...

Page 11: ...esignated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage WARNING 7 Switch Cup Manual Control 7 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box Check the operation of the fan by gently p...

Page 12: ...tore or catalog 9 Accessories The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the onl...

Page 13: ...twist and unkink the 80 accent light harness yellow wire supplied with the fan Join the 80 accent light harness yellow wire to the motor housing yellow connector Figure 21 Feed the accent light harness yellow wire through the down rod coupler cover and ceiling cover NOTE The red and brown wires coming from the top of the motor are capped with wire connectors DO NOT remove these connectors 10 3 An ...

Page 14: ...sing three AL100 accent light mounting screws Figure 22 AL100 ACCENT LIGHT HARNESS AL100 ACCENT LIGHT HARNESS SCREW 3 MOTOR ASSEMBLY Figure 22 11 2 Securely connect the AL100 accent light connector to the motor assembly connector Figure 23 Screw the four 25 watt candelabra base bulbs supplied into the AL100 accent light sockets Figure 23 NOTE When installing an AL100 Accent Light an Emerson Access...

Page 15: ...e connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 4 Screws holding blades to flywheel 4 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Ti...

Page 16: ... discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER BP7480 CF5100 PENBROOKE SELECT 12 18 13 10 35 AM Page 16 ...

Page 17: ...oupler Cover 1 764412 BS 764412 GES 764412 ORB 764412 SW 764412 VNB 764412 VS 21 Wiring Harness 1 764422 1 764422 764422 764422 1 764422 764422 22 Auxiliary Capacitor 1 763493 763493 763493 763493 763493 763493 23 Hub Rubber 1 760601 760601 760601 760601 760601 760601 24 Spacer Hub 764420 764420 764420 764420 764420 764420 25 Lockwasher 9 16 762508 762508 762508 762508 762508 762508 26 Motor 76250...

Page 18: ...18 U L Model No CF5100 NOTES BP7480 CF5100 PENBROOKE SELECT 12 18 13 10 35 AM Page 18 ...

Page 19: ...eturn your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan t...

Page 20: ...Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74800000 Form No BP7480 Revision 131218 U L Model No CF5100 Printed in China 12 13 BP7480 CF5100 PENBROOKE SELECT 12 18 13 10 35 AM Page 20 ...

Reviews: