7
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF5100
3. Ceiling Fan Assembly
(continued)
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
HAIRPIN
CLIP
MOTOR
COUPLING
SETSCREW (2)
CLEVIS PIN
DOWNROD
Figure 8
3.8
Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80” motor leads.
Route the motor lead wires through the downrod. Align
the clevis pin holes in the downrod with the holes in the
motor coupling. Install the clevis pin and secure with the
hairpin clip (Figure 8). The clevis pin must go through
the holes in the motor coupling and the holes in the
downrod. Be sure to push the straight leg of the hairpin
clip through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around the
clevis pin. The hairpin clip must be properly installed to
prevent the clevis pin from working loose. Pull on the
downrod to make sure the clevis pin is properly
installed.
DOWNROD
PIN
SETSCREW
HANGER BALL
Figure 7
3.7
Remove the hanger ball by loosening the setscrew in
the hanger ball until the ball falls freely down the
downrod (Figure 7). Remove the pin from the downrod,
then remove the hanger ball. Retain the pin and hanger
ball for reinstallation in Step 3.13.
SETSCREW (1)
5/32"
SETSCREW
WRENCH
MOTOR
COUPLING
Figure 9
3.9
Install the setscrew (supplied in loose parts bag) in the
motor coupling and tighten using the 5/32" setscrew
wrench (supplied) (Figure 9).
It is critical that the clevis pin in the motor coupling is
properly installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are properly
installed could result in the fan falling.
WARNING
!
BP7480 CF5100 PENBROOKE SELECT 12/18/13 10:35 AM Page 7