PACMotion™ Servos Accessories Guide
Section 6
GFK-3173C
December 2020
Capacitor Modules
15
6.2
Order Codes
The KCM modules may only be connected to drives with 400/480 V rated voltage.
Type/Order Code
Remarks
KCM-S200-0000
Energy Saving Module, 1.6 kWs
KCM-P200-0000
Power Module, 2 kWs
KCM-E200-0000
Expansion Module 2 kWs
KCM-E400-0000
Expansion Module 4 kWs
6.3
KCM Module
Observe the safety instructions and in the instruction manual of the drive.
Permissible assembly type: Vertical, ground connections at the bottom. Other assembly positions are not
permitted. Observe the required free space to the next device. Ensure there is unobstructed convection for
cooling purposes.
6.3.1
Technical Data
Type
Storage
Capacity
[Ws]
Rated supply
voltage[V=]
Peak
supply
voltage
[V=]
Power
[kW]
Protection
Class
Inception
voltage [V=]
Weight
[kg]
KCM-
S200
1600
max 850 VDC
max
950VDC
(30s in
6min)
18
IP20
calculated
6.9
KCM-
P200
2000
470 VDC
6.9
KCM-
E200
2000
-
4.1
KCM-
E400
4000
-
6.2