Chapter 2
NITX-300-ET-DVI Installation and Use (6806800N97A)
21
Hardware Preparation and Installation
2.1
Environmental and Power Requirements
2.1.1
Environmental Requirements
The following tables list the environmental requirements that NITX-300-ET-DVI board must
meet when operated in your particular system configuration.
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying power.
Table 2-1 Environmental Requirements of NITX-300-ET-DVI
Requirement
Operating
Non-Operating
Cooling Method
Fanless
Temp Cycle Class
-40-+85C:500cyc
Temperature
-40 °C to +85 °C
-40 °C to +85 °C
Humidity
10-90% (non-condensing)
Vibration
.01 g^2/Hz @ 5-500Hz
Shock
20g 11ms sine or saw
Altitude
-60 - 4000 m ASL
Summary of Contents for NITX-300-ET-DVI
Page 10: ...NITX 300 ET DVI Installation and Use 6806800N97A 10 List of Figures ...
Page 32: ...Hardware Preparation and Installation NITX 300 ET DVI Installation and Use 6806800N97A 32 ...
Page 90: ...BIOS NITX 300 ET DVI Installation and Use 6806800N97A 90 ...
Page 92: ...Operating System and Driver Support NITX 300 ET DVI Installation and Use 6806800N97A 92 ...
Page 95: ...Replacing the Battery NITX 300 ET DVI Installation and Use 6806800N97A 95 ...
Page 96: ...Replacing the Battery NITX 300 ET DVI Installation and Use 6806800N97A 96 ...
Page 98: ...Related Documentation NITX 300 ET DVI Installation and Use 6806800N97A 98 ...
Page 108: ...NITX 300 ET DVI Installation and Use 6806800N97A Sicherheitshinweise 108 ...
Page 109: ......