3.5. Requirements for the Operator

This means people who are familiar with the erection, installation, commissioning, operation and 
maintenance of the product and have appropriate qualifications relating to their activities and 
functions, such as e.g.:
-  instruction in and duty to comply with all installation-related, regional and internal works 

regulations and requirements

-  training or instruction in accordance with the Safety Standards for personal care and use of 

appropriate safety equipment and protective workgear, like e.g. personal protection equipment 
(insulated gloves or similar), suitable for the operating conditions.

Furthermore, these people must have read and understood these instructions.

3.6. Transport/Storage

The valve is delivered with protective covers which should protect against soiling and mechanical 
effects. For this reason, the protective covers should only be removed immediately prior to 
installation.
The ball valve is shipped in the closed position.

3.7. Transport and storage conditions

-  transport and storage temperature -20° to +65°C
-  protect against external force(impact, shock, vibration)
-  do not damage the coating
-  in damp storage areas, a drying agent or heating is required to protect against condensation
-  store the ball valve in a slightly open position

4. Identification

Each ball valve is fitted with a rating plate giving information on valve type and origin. When 
ordering spare parts this information should be carefully noted down each time.
Ball valves in the size range DN15 to DN25 have a standard rating plate with no CE mark. Ball 
valves in the size range DN40 to DN150 are provided with a rating plate with a CE mark.
Additional identification on the valve in accordance with DIN 19, such as:

DN, PN, manufacturer’s logos of the Neotecha AG company            . The identification of the valve 

body material is cast onto the valve.

3.8. Handling prior to installation

-  on versions with protective covers, only remove these immediately prior to installation!
-  protect against the effects of weather, e.g. dampness (or else use a drying agent)
-  proper treatment prevents damage

5. Dimensions and Weights

Please refer to the product documentation for any dimensions that are not contained in the 
installation and maintenance instructions and for ball valve weights..

6. Installation

6.1. Installation in the pipeline

Fit the ball valve in the pipeline, ensuring that the sealing surfaces on the faces of the flanges are 
not damaged. The SNB ball valve can be installed independently of the direction of flow. On the 
other hand, the SNC can only be installed in one direction, i.e. the arrow on the side of the valve 
must point in the direction of flow. Adequate clearance should be ensured around the ball valve, so 
that it can be operated and maintained easily.
The mounting flanges of the pipeline in which the valve is to be installed must be aligned axially 
and laterally, in order to prevent the valve body being subjected to additional stresses. Fit suitable 
flange packings, provided that they are called for: then the fixing bolts are inserted. Tightening the 
bolts in stages is essential for an equal distribution of the of the initial stress force of the clamping 
bolts.
The specified tightening torques must not be exceeded.

The flanges must meet the following requirements: cleaned and undamaged mating surface.

Flange packings are not required with flanges with flat sealing surfaces. Additional packings may 
possibly be required with rubberized flanges.

Manufacturer

Origin

Serial number

Manufacturer’s code

Ball valve type

Year of manufacture

Number of the 

notified body

Summary of Contents for NEOTECHA SNB Series

Page 1: ...tional regulations are complied with The manufacturer reserves all rights to make technical changes and improvements at any time The use of these installation and maintenance instructions assumes that the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 Safety Please also read through these notes caref...

Page 2: ...emperature of the valve can be up to a maximum of 200 C Suitable precautions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 3 5 Usage Restrictions Before the valve is installed a check shou...

Page 3: ... a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve body material is cast onto the valve 3 8 Handling prior to installation on versions with protective covers only remove these immediately prior to installation protect against the effects of weather e g dampness...

Page 4: ... various intermediate positions version Z In addition the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6...

Page 5: ...ening torques for SNB SNC ball valves DIN PN16 and JIS 10K Recommended torques DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for SNB SNC ball valves ANSI B 16 10 class 150 lbs 6 8 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the valve spread the mounting flanges apart sufficiently using a suitable...

Page 6: ...lves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an SNC series C valve should be used This type can also be fitted with various control orifice plates Refer to the flow characteristic d...

Page 7: ...so that the possible cause of damage can be determined after removal Attention Check that the pipe is depressurized and drained With corrosive inflammable aggressive or toxic media ventilate the pipeline system Only allow assembly work to be carried out by qualified personnel see Section 2 3 Almost fully close the valve note position of the flat sections of the control shaft Loosen all flange bolt...

Reviews: