SNB-SNC ball valves

Installation and Maintenance Instructions

 without notice 

NEOJV-0044-EN-1306

These installation and maintenance instructions must 

be read in full and completely understood before the 

installation!

Contents

1  General information on the installation 

and maintenance instructions 

1

2 Safety 

1

3  Sources of Danger 

2

4 Identification 

3

5  Dimensions and Weights 

3

6 Installation 

3

7  Notes on dangers during  

installation, operation and 
maintenance 

6

8 Commissioning 

6

9 Use 

6

10  Servicing and Maintenance 

6

11  Cause and remedy of  

operating faults 

7

12 Decommissioning 

7

13  Spare parts 

7

14 Disposal 

7

15  Customer service 

7

16  Validity of the Installation and 

Maintenance Instructions 

7

1. General information on the installation and maintenance instructions

These instructions contain information on how the valve should be safely installed and operated 
in the prescribed manner. If any problems are encountered during installation or operation which 
cannot be resolved with the aid of the installation and maintenance instructions, please contact the 
supplier or manufacturer for more information.
These installation and maintenance instructions comply with the applicable EN safety standards.
When installing the fitting, the operator or the person responsible for the design of the installation 
must ensure that applicable national regulations are complied with.
The manufacturer reserves all rights to make technical changes and improvements at any time.
The use of these installation and maintenance instructions assumes that the user is qualified to 
‘Qualified Personnel’ level. Operating staff must be given appropriate training in the operating and 
maintenance instructions.

2. Safety

Please also read through these notes carefully.

2.1. Meaning of the symbols

This symbol in the operating instructions indicates dangers.

2.2. General potential danger due to:

a) failure to observe the instructions
b) improper use
c) insufficiently qualified personnel

2.3. Correct Use

2.3.1. Area of application

Ball valves are bubble-tight shut-off industrial valves that can be used for the isolation, throttling 
and regulation of corrosive gases, liquids, pastes and powder products in pipelines, vessels, 
apparatus etc.
The surfaces of the of the body parts, together with the ball or C-core that are in contact with the 
medium are coated with PFA. Ball seats and control orifice plates are available in various material 
types and can be used to suit the medium.

2.3.2. Performance Data

Nominal diameter range  : 

DIN-PN16 and JIS 10K

 

  DN 15 / 20 / 25 / 40 / 50 / 65 / 80 / 100 / 150

 

  (ANSI 6” face-to-face with extension)

  

ANSI 150 lbs

 1/2”, 3/4”, 1”, 1 1/2”, 2”, 2 1/2”

 

  (DIN face-to-face), 3”, 4”, 6”

Pressure range 

:  16 bar (0.1 mbar vacuum)

 

  Test pressure = 1.5 x PN = 24 bar

Temperature range 

:  -40° to 180°C

2.3.3. Pressure-Temperature diagram for SNB-SNC ball valves

bar

Vacuum

NEOTECHA

Emerson.com/FinalControl

© 2017 Emerson. All rights reserved.

Summary of Contents for NEOTECHA SNB Series

Page 1: ...tional regulations are complied with The manufacturer reserves all rights to make technical changes and improvements at any time The use of these installation and maintenance instructions assumes that the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 Safety Please also read through these notes caref...

Page 2: ...emperature of the valve can be up to a maximum of 200 C Suitable precautions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 3 5 Usage Restrictions Before the valve is installed a check shou...

Page 3: ... a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve body material is cast onto the valve 3 8 Handling prior to installation on versions with protective covers only remove these immediately prior to installation protect against the effects of weather e g dampness...

Page 4: ... various intermediate positions version Z In addition the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6...

Page 5: ...ening torques for SNB SNC ball valves DIN PN16 and JIS 10K Recommended torques DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for SNB SNC ball valves ANSI B 16 10 class 150 lbs 6 8 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the valve spread the mounting flanges apart sufficiently using a suitable...

Page 6: ...lves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an SNC series C valve should be used This type can also be fitted with various control orifice plates Refer to the flow characteristic d...

Page 7: ...so that the possible cause of damage can be determined after removal Attention Check that the pipe is depressurized and drained With corrosive inflammable aggressive or toxic media ventilate the pipeline system Only allow assembly work to be carried out by qualified personnel see Section 2 3 Almost fully close the valve note position of the flat sections of the control shaft Loosen all flange bolt...