18
Reference Manual
24625020, Rev AA
March 2017
2.3
Mounting electrodes on a manifold
Note
See
“Mounting an electrode to an insert” on page 11
for the alternative mounting method.
Procedure
1.
Remove the electrode covers and port dust caps.
2.
Temporarily cover the manifold ports with heat-resistant material, to prevent the
ingress of weld splatter and dirt.
3.
Weld the manifold in place, using the procedure recommended by the National or
Regional Codes of Practice.
4.
Install electrodes in the manifold ports.
(The fitting procedure is described in
“Fitting the electrode” on page 15
).
5.
Replace the electrode covers and secure them.
2.4
Customized manifolds
show details of two- and four-port customized manifolds. These
manifolds can be made-to-order to customer requirements. They are side-coupled to the
connecting pipework and vertically mounted. Separate vent and drain connections are
provided.
Even if the electrode cable is soon to be connected, it is advisable to complete the
installation of the cover rather than leave the electrode exposed to possible damage.
The cover should be removed just prior to fitting the cable and then re-fitted
immediately afterwards.