The gap between the electronics housing and sensor body should be inspected
periodically. Manually clean this gap when necessary.
•
Tri-Clamp
®
and DIN 11851 style process connections require special gaskets to comply
with EHEDG requirements for hygienic design.
Figure 2-1: Sensor inclination
$
%
A. Angle of inclination
B. Direction of gravity
Table 2-3: Minimum angle of inclination
Model
Fitting
code
Description
Min. angle
T025F, T025T
621
0.5 in (13 mm) Tri-Clamp compatible sanitary
clamp
47°
670
DN10 DIN 11851 sanitary coupling
47°
671
DN15 DIN 11851 sanitary coupling
47°
676
DN15 DIN 11864-1A sanitary coupling
47°
T050F, T050T
621
0.5 in (13 mm) Tri-Clamp compatible sanitary
clamp
0°
671
DN15 DIN 11851 sanitary coupling
47°
676
DN15 DIN 11864-1A sanitary coupling
47°
T075F, T075T
622
0.75 in (19.0 mm) Tri-Clamp compatible sanitary
clamp
0°
623
1 in (25 mm) Tri-Clamp compatible sanitary clamp
47°
662
DN25 ISO 2853 (IDF) sanitary coupling
47°
672
DN25 DIN 11851 sanitary coupling
47°
677
DN25 DIN 11864-1A sanitary coupling
47°
692
DN25 SMS 1145 sanitary coupling
32°
T100F, T100T
623
1 in (25 mm) Tri-Clamp compatible sanitary clamp
0°
Planning
Installation Manual
February 2020
20002172
10
Micro Motion T-Series
Summary of Contents for Micro Motion T Series
Page 4: ...Contents Installation Manual February 2020 20002172 iv Micro Motion T Series ...
Page 12: ...Planning Installation Manual February 2020 20002172 12 Micro Motion T Series ...
Page 16: ...Mounting Installation Manual February 2020 20002172 16 Micro Motion T Series ...
Page 24: ...Grounding Installation Manual February 2020 20002172 24 Micro Motion T Series ...
Page 27: ...Installation Manual 20002172 February 2020 Installation Manual 27 ...