background image

Part No. F40BP75150000

Form No. BP7515

Revision: 160104 

ETL Model No.: CF860

READ AND SAVE THESE INSTRUCTIONS

LURAY ECO

60” Damp Location

Ceiling Fan Owner's Manual

Model Numbers

Net Weight: 

20.02

Lbs.

Questions, problems, missing parts:  Before returning to the store call

Emerson Electric Customer Service   -  8 a.m. - 6 p.m., Eastern, Monday-Friday

1-800-654-3545

www.emersonfans.com

•  Español - página 34
•  Français - page 67

CONTEMPORAR

Y

CF860BQ00 -

Barbeque Black

CF860PT00 - 

Platinum

CF860WW00 - 

Appliance White

BP7515 CF860 Luray Eco  1/4/16  2:35 PM  Page 1

Summary of Contents for LURAY ECO CF860BQ00

Page 1: ...l Numbers Net Weight 20 02 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Español página 34 Français page 67 CONTEMPORARY CF860BQ00 Barbeque Black CF860PT00 Platinum CF860WW00 Appliance White BP7515 CF860 Luray Eco 1 4 16 2 35 PM Page 1 ...

Page 2: ...lectrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7kg 50 lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qua...

Page 3: ...OTE If you are uncertain of part description refer to exploded view illustration NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding G K F H C B I J D E A PACKAGE CONTENTS 9 7 1 2 3 4 6 5 8 Part Description Quantity A Fan Motor Assembly 1 B Hanger Bracket 1 C Hanger Bal...

Page 4: ...e the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To av...

Page 5: ...ounting flange with three holes aligns with the three matching holes of the motor Figure 2 The two bottom blade mounting tabs should align with the mating mounting ears on the other side of the motor Install three screws into the blade holes and loosely fasten to the motor with a Phillips tip screw driver Repeat this for each of the other two blades Be careful to align the edge of each blade with ...

Page 6: ...f the three pan head screws from the motor assembly hub retain the screw for future use Loosen the remaining two screws Figure 3 Place the two motor assembly wires through the large center hole of the light kit adapter Figure 3 Position the light kit adapter key hole slots onto the two loosened screw heads Rotate the switch housing adapter clockwise to engage the two screws Verify that the serrate...

Page 7: ...holes of one blade with the threaded holes of the motor and install a washer head screw into each hole Figure 5 Loosely fasten each screw into the motor ear It will be necessary push on the blade with your hand to align the holes Have patience during this step Repeat the washer head screw installation for each of the remaining blades Fully tighten all six screws when the mating blade edges are ali...

Page 8: ...OTOR COUPLING CLEVIS PIN HAIRPIN CLIP Figure 9 3 9 Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 9 The clevis pin must go through the holes in the motor coupler It is critical that the clevis pin in the motor coupler is properly installed and securely tightened Evenly retighten the two Phillips head sets...

Page 9: ...the hanger ball Figure 12 Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball Figure 12 Loose setscrew could create fan wobble 4 5 DOWNROD CEILING COVER Figure 11 3 11 Place the ceiling cover over the downrod Figure 11 Be sure that the ceiling cover and the motor coupler cover are both oriented correctly Figure 11 COUPLER COVER GROMMET COUPLER COVER 4...

Page 10: ...e sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with N...

Page 11: ...mblies while hanging the partially assembled ceiling fan The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7 kg 50 lbs or less WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use s...

Page 12: ...r LIGHT KIT ASSEMBLY REINSTALL LIGHT KIT ADAPTER PAN HEAD SCREW LIGHT KIT ADAPTER ROTATE COUNTER CLOCKWISE Figure 18 LIGHT KIT ADAPTER RAISED DIMPLES 3 SHADE FLAT AREA OF SHADE 3 ROTATE CLOCKWISE Figure 19 To avoid possible fire or shock do not pinch wires between the Light Kit Assembly and the Light Kit Adapter WARNING 5 1 Remove one of the three screws in the Light Kit Adapter and loosen the rem...

Page 13: ...two screw heads in the key hole slots for removal of Light Kit Assembly LOOSENED LIGHT KIT ADAPTER PAN HEAD SCREWS 2 LIGHT KIT ASSEMBLY LIGHT KIT ADAPTER PAN HEAD SCREW 1 LIGHT KIT ADAPTER ROTATE COUNTER CLOCKWISE Figure 21 6 3 Disengage the fan motor assembly black wire connector into the black wire connector of the Light Kit Assembly Figure 22 Disengage the fan motor assembly white wire connecto...

Page 14: ...RNING GROUND CONDUCTOR SUPPLY LISTED WIRE CONNECTOR GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL Figure 24 6 Optional Installation No Light Plate Assembly Continued 6 4 Carefully tuck all the wires into the Light Kit Adapter Place the no light plate into the opening of the Light Kit Adapter aligning the three flat areas on the top edge of the no light plate with the thr...

Page 15: ...ush leads into the outlet box with the white and green leads on one side of the outlet box and position the black lead on the other side of the outlet box Figure 27 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING LIST...

Page 16: ...readed studs and turn until studs protrude through the holes in the ceiling cover Figure 29 Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 29 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod 7 5 Screw the two thre...

Page 17: ...Light Kit Assembly LOOSEN LIGHT KIT ADAPTER PAN HEAD SCREWS 2 LIGHT KIT ASSEMBLY LIGHT KIT ADAPTER PAN HEAD SCREW 1 ROTATE CLOCKWISE Figure 31 Repair of the Light Kit can be Accomplished By 1 Replacing the Entire Light Kit Assembly or 2 Replacing the Driver or Array Components Individually Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned of...

Page 18: ...m of the Driver Figure 34 Remove the old Light Kit Assembly Driver Discard the Light Kit Assembly in the correct recycle bin LIGHT KIT ASSEMBLY LIGHT KIT ASSEMBLY DRIVER ADHESIVE FOAM TAPE Figure 34 8 4 Disengage the fan motor assembly black wire connector from the black wire connector of the new Light Kit Assembly Figure 32 Disengage the fan motor assembly white wire connector from the white wire...

Page 19: ...tape on the bottom of the new Light Kit Assembly Driver Place the new Light Kit Assembly Driver into the assembly aligning it directly where the old Driver had been Figure 35 Press firmly on the Light Kit Assembly Driver to adhere it to the Light Kit Assembly If Also Replacing the LED Array Proceed to Instruction 8 12 If Finished Re connect the Light Kit Assembly Driver two pin connector to the Li...

Page 20: ...n the new Light Kit Assembly Array onto the Light Kit Assembly NOTE Handle the new Light Kit Assembly Array around the edges of the Light Kit Assembly Being careful not to touch the LED diodes located on the Light Kit Assembly Array Reattach the new Light Kit Assembly Array by installing the three plastic Phillips head screws provided with new replacement kit Figure 38 LIGHT KIT ASSEMBLY ARRAY DO ...

Page 21: ...ure If the AC supply to the receiver is powered OFF through a wall switch the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF 8 Light Kit Assembly Replacement Continued 8 17 Reconnect the fan motor assembly black wire connector into the black wire connector of the Lig...

Page 22: ...ctions using wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 9 4 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan wall control into the outlet box CAUTION To reduce the risk of electrical shock disconn...

Page 23: ...to wall box using the supplied screws Leave wall control in OFF mode until fan installation is completed The wall control is supplied with a white ivory and almond color switch covers Choose the finish that best suits your needs and snap the cover onto the wall control Figure 43 Install decorator wall plate using the two screws provided with wall plate Leave wall control in OFF mode until fan inst...

Page 24: ...T WALL CONTROL TRAVELER WIRE BLK BLK LOAD GROUND NEUTRAL BLACK BLK RECEIVER LOCATED WITHIN THE CEILING COVER OF THE CEILING FAN Figure 45 Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be proper...

Page 25: ...d Figure 46 Check to see that all connections are tight and that no bare wires are visible at the wire connectors WARNING STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTROL FAN LIGHT WALL CONTROL BLK BLACK LOAD TRAVELER WIRES HOT BLK BLK FAN LIGHT WALL CONTROL BLK 3 WAY WIRING DIAGRAM RETROFIT 25 emersonfans com Please contact 1 800 654 3545 for fur...

Page 26: ...after successful pairing the ceiling fan will automatically begin high speed conditioning of the motor During conditioning the electronic motor control software is calculating speeds for the 2nd through 5th speed settings based on the blades that were installed on the fan The fan will run for approximately 1 minute in the upward direction then reverse direction to down flow and run an additional 1...

Page 27: ...ously selected Figure 47 If airflow is desired in the opposite direction press the button on the wall control The fan must be operating at any speed for the reverse button to function The blades will turn in the opposite direction and reverse the airflow Your wall control comes complete with your choice of three wall cover plates ivory white and light almond Figure 47 Your fan is now wired to be t...

Page 28: ...n performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 2 1 m above the floor and 46 cm from the walls If ceiling height allows install the fan 2 5 m 2 75 m above the f...

Page 29: ...holding blades to motor are 3 Tighten screws securely loose 3 Fan wobbles 1 Setscrews in motor coupler are loose 1 Tighten both setscrews securely in the motor coupler excessively 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball downrod assembly is loose assembly 3 Screws securing fan blades to 3 Check to be sure screws which attach the fan blades motor are loose to the ...

Page 30: ...30 ETL Model No CF860 16 Repair Parts PARTS BAG 13 3 1 2 5 17 20 21 14 7 6 8 9 11 22 11 18 10 10 15 16 23 11 10 8 9 7 6 5 4 19 12 BP7515 CF860 Luray Eco 1 4 16 2 35 PM Page 30 ...

Page 31: ...4748 BLOX 764748 CHRM 764748 CRM 4 Wire Connectors 5 5 Studs Threaded 8 32 x 1 1 4 2 6 Lockwashers External Tooth 8 2 7 Knobs Knurled 8 32 2 8 Pin Clevis 1 9 Clip Hairpin 1 10 Washer Head Screw 8 32 x 50 16 11 Pan Head Screw 6 32 x 375 Spares 2 12 Blade Balancing Kit 1 13 Ceiling Cover 1 764733 BQ 764733 PT 764733 WW 14 Motor Coupler Cover 1 764734 BQ 764734 PT 764734 WW 15 DC Motor Controller 1 7...

Page 32: ...ct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This equipment has been certified to comply with the limits for a ...

Page 33: ...ser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain you...

Page 34: ...ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP75150000 Form No BP7515 Revision 160104 ETL Model No CF860 Printed in China 01 04 SERIAL NUMBER DATE CODE The serial number of this fan can be found on the nameplate on top of the fan housing The date code can be found on the carton stamped in ink on a white label You should record this data above and keep it in a safe place for future u...