background image

Type N201

6

Figure 4.

  Type N201 Assemblies (continued)

  5.  Remove orifice (key 3) and unscrew the disk 

       holder assembly (key 5).  Examine and replace 

       if necessary.  
  6.  Remove bushing (key 8) and take out the O-ring 

       (key 7).  Examine and replace if necessary.  Put 

       Dow Corning #3 grease (or equivalent) on 

       the O-ring (key 7). 
  7.  Make sure all parts are clean before reassembling.

To reassemble   

  1.  Replace orifice (key 3) in valve head (key 1). 
  2.  Replace O-ring (key 7) and screw in bushing 

       (key 8).

  3.  Replace disk holder assembly (key 5) and 

       spring (key 21).  Screw the disk holder into the 

       diaphragm head (key 9).     
  4.  Replace upper diaphragm (key 10) on the valve 

       head (key 1).  Align the valve housing (key 2), 

       spring (key 35), lower diaphragm assembly 

       (key 32), and valve body (key 17) so that the cap 

       screws (key 22) can be inserted.    
  5.  Connect tubing (key 39) to angle adaptor in  

        Type 67/683 (key 30). 

 

inl
ET

50

48

49

51

CH1624

28

31

TyPE 67CW-684

TyPE 67CW-685

Summary of Contents for Fisher N201 Series

Page 1: ...e scale beam contacts the trip valve see B in Figure 2 The trip valve opens to exhaust pressure from under the lower diaphragm Spring force opens the lower valve allowing pressure from regulator 2 to register on the upper diaphragm This closes the upper valve and stops flow through the orifice A red button indicates that the filler valve is closed and that the cylinder is full Removing the full cy...

Page 2: ...ade This is usually necessary when both 20 pounds 9 kg and 100 pounds 45 kg cylinders are to be filled Follow steps 3 a b c and d Place the beam button J on the scale beam close enough to the pivot point to allow the slide weight to move to zero If there is not enough room to permit this either the beam button must be ground down or the user must make a special beam button e Mount beam bar K on th...

Page 3: ...int d Attach the beam bar L to the clamp M with two screws and attach the clamp to the rear of the scale beam with two screws e Remove locknut D and insert the trip valve through the 5 8 inch 16 mm hole Replace locknut f Using locknut D and E position trip valve so that it barely contacts the beam bar L with the scale in a level position 4 Connect supply pressure air or gas at point P Recommended ...

Page 4: ...lide beam weight H to the tare weight stamped on the cylinder open the hose shutoff valve and the cylinder valve and the Type N201 will fill the cylinder to the weight added on the scale pan Note When operating with high pump pressure the filler valve may close off then reopen for a short spurt and close off again This is due to the force of the incoming liquid stream If the proper cylinder weight...

Page 5: ...Type N201 5 Figure 4 Type N201 Assemblies CH1624 11 button and bar for Attachment to scale beam 15 10 9 18 20 19 5 3 7 6 8 1 21 34 33 38 40 36 37 23 46 25 45 39 22 17 16 14 32 35 13 45 2 42 44 43 41 24 ...

Page 6: ...bling To Reassemble 1 Replace orifice key 3 in valve head key 1 2 Replace O ring key 7 and screw in bushing key 8 3 Replace disk holder assembly key 5 and spring key 21 Screw the disk holder into the diaphragm head key 9 4 Replace upper diaphragm key 10 on the valve head key 1 Align the valve housing key 2 spring key 35 lower diaphragm assembly key 32 and valve body key 17 so that the cap screws k...

Page 7: ...ip Valve Body Brass 1F945014012 25 Inner Valve Brass 20B9389X012 28 Pipe Plug Steel not shown 1A3619X0012 32 Diaphragm Assembly 1H1615000A2 33 Pipe Nipple 3 required 1C488226232 34 Tee Malleable iron 1C597547362 35 Spring Steel 1F944627212 36 Compression Elbow Brass 2 required 15A6002X172 37 Nut 2 required 1H262224122 38 Hose Assembly 1J152299012 39 Tubing Assembly Copper T20048000A2 40 Street Elb...

Page 8: ...n or their use or applicability We reserve the right to modify or improve the designs or specifications of such products at any time without notice Emerson Process Management does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any Emerson Process Management product remains solely with the purchaser Emerson Pr...

Reviews: