Type N201
3
l
PiVOT
POinT
m
F
BEam
hOrizOnTal
(lEVEl)
BEam in raisED
POsiTiOn
D
E
sTanDarD TriP ValVE
insTallaTiOn
maniFOlD
sCalE FramE
h
TriP ValVE
2 PiVOT
POinT
C
i
P
h
K
J
TriP ValVE
3 (76)
1-1/4
(32)
inChEs
(mm)
TriP
ValVE
J
J
BEam WhEn CylinDEr
is nOT FillED
sCalE
FramE
BEam sTOP
sCalE BEam
FrOm Charging PumP
TriP ValVE
hOsE
TyPE n201
FillEr ValVE
PilOT VaPOr
PrEssurE FrOm
air COmPrEssOr
sTOragE TanK,
Or auXiliary
PrOPanE CylinDEr
sCalE BEam
Filling hOsE
aPPrOX. 1/5
lEngTh OF
sCalE BEam
alTErnaTE TriP ValVE insTallaTiOn # 2
(FOr TyPEs 1124a anD 1280a FairBanKs mOrsE sCalE)
alTErnaTiVE TriP ValVE
insTallaTiOn #1
a
B
c. Drill a 5/8-inch (16 mm) hole through the scale
frame at this point.
d. Attach the beam bar “L” to the clamp “M” with
two screws, and attach the clamp to the rear
of the scale beam with two screws.
e. Remove locknut “D” and insert the trip valve
through the 5/8-inch (16 mm) hole.
Replace locknut.
f. Using locknut “D” and “E”, position trip
valve so that it barely contacts the beam
bar ”L” with the scale in a
level position.
4. Connect supply pressure (air or gas) at point “P”.
Recommended supply pressure is at least 30 psig
(2,1 bar), since regulator 2 is set at 30 psig
(2,1 bar) outlet pressure. A 30 psig (2,1 bar)
supply is sufficient for pump discharge pressures
up to 350 psig (24,1 bar). Regulator 1 is set at
3 psig (0,21 bar).
note
if propane vapor pressure is used,
atmospheric or room temperature below
8°F (-13°C) will limit supply pressure to
below 30 psig (2,1 bar). To assure tight
shutoff of the filler valve in this event,
refer to Table 1.
Figure 3.
Type N201 Installation