Valve Orientation
The valve can be installed in any orientation, however it is recommended that the valve drive shaft be horizontal and
the actuator vertical as shown in figure 4.
Install the valve with the high‐pressure shutoff side in the direction noted by the flow arrow for proper installation, and
see figure 4 for more information.
Before Installing the Valve
WARNING
The edges of a rotating valve disk (key 2, figure 9 or 10) close with a shearing, cutting motion. To avoid personal injury,
keep hands, tools, and other objects away from the disk while stroking the valve.
If the 8532 valve is equipped with a fail‐open actuator, cycle the valve into the fully closed position. Ensure the valve cannot
open during installation by using travel stops, a manual actuator, a constant supply pressure to the pneumatic actuator, or
other steps as necessary.
Table 3. Valve Body Data, CL150
VALVE SIZE,
NPS
SHAFT DIA. AT
YOKE BEARING
FACE‐TO‐FACE DIMENSION
(1)
MINIMUM
I.D
.(2)
APPROXIMATE WEIGHT, KILOGRAMS
Wafer and
Lugged
Double-Flange
mm
Wafer
Lugged
Double-Flange
14
30.2
92.1
191
331.2
71.7
94.8
152
16
31.75
101.6
216
375.2
93.9
137.9
201
18
38.1
114.3
222
418.8
139.3
178.3
243
20
44.45
127.0
229
464.1
166.9
223.6
277
24
57.15
154.0
267
580.9
255.4
350.6
434
VALVE SIZE,
NPS
SHAFT DIA. AT
YOKE BEARING
FACE‐TO‐FACE DIMENSION
(1)
MINIMUM
I.D
.(2)
APPROXIMATE WEIGHT, POUNDS
Wafer and
Lugged
Double-Flange
Inches
Wafer
Lugged
Double-Flange
14
1‐3/16
3.625
7.50
13.04
158
209
335
16
1‐1/4
4
8.50
14.77
207
304
443
18
1/2
4.5
8.75
16.49
307
393
535
20
1‐3/4
5
9.00
18.27
368
493
611
24
2‐1/4
6.0625
10.50
22.87
563
773
956
1. Face‐to‐face dimensions are in compliance with MSS SP68 and API 609 specifications.