Parts Ordering

Typical parts are shown in figures 9 and 10.

When corresponding with your 

Emerson sales office

 or Local Business Partner about an 8532 valve, identify the valve

as a Fisher 8532 and provide the valve serial number. For valve/actuator combinations assembled at the factory, the
valve serial number may be stamped on the nameplate attached to the actuator.

  WARNING

Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Automation Solutions should
not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the
performance of the valve, and could cause personal injury and property damage.

Retrofit Kits

Retrofit kits include all parts required for installation of the ENVIRO‐SEAL packing system into existing
high‐performance butterfly valves. Retrofit kits are available for single PTFE packing.

See table 7 for retrofit kit part numbers.

Retrofit Kit Included Parts

Key

Description

Quantity

10
17

100
101
102
103
105
106
107
111
112

Anti‐blowout follower

Jam nut

Packing stud

Packing nut

Packing flange

Spring pack assembly

Packing Set

Anti‐extrusion washer

Packing box ring

Tag

Cable

1
1
2
2
1
1
1

2

(1)

2

(2)

1
1

1. Not included in graphite packing kit.
2. Only 1 req'd for NPS 18 CL300, NPS 20 CL150 and NPS 24 CL150.

Note

Key 103, the spring pack assembly, is made up of the packing spring stack held in place by an O‐ring on the packing follower.

Summary of Contents for Fisher 8532

Page 1: ...truction manual provides installation maintenance and parts information for NPS 14 through 24 Fisher 8532 high performance butterfly valves Do not install operate or maintain an 8532 valve without being fully trained and qualified in valve actuator and accessory installation operation and maintenance To avoid personal injury or property damage it is important to carefully read understand and follo...

Page 2: ...tio 2 100 to 1 Noise Levels See Fisher Catalog 12 for sound pressure level prediction Valve Body Classification Wafer and Lugged face to face dimensions are in compliance with MSS SP68 and API 609 standards Double Flange valve bodies comply with API 609 short face to face dimensions Valve bodies are designed for installation between ASME B16 5 CL150 and CL300 raised face flanges Disk Rotation Cloc...

Page 3: ... Backup O Ring PTFE Backup O Ring 29 to 93 43 to 149 54 to 182 29 to 204 73 to 204 20 to 200 45 to 300 65 to 360 20 to 400 100 to 400 UHMWPE 5 Seal Ring CL150 Only EPR Backup O Ring Fluorocarbon Backup O Ring 54 to 93 29 to 93 65 to 200 20 to 200 Phoenix III and or Fire Tested Construction S31600 and PTFE Seal Ring with Nitrile Backup O Ring Chloroprene Backup O Ring EPR Backup O Ring Fluorocarbon...

Page 4: ...N When ordered the valve configuration and construction materials were selected to meet particular pressure temperature pressure drop and controlled fluid conditions Responsibility for the safety of process media and compatibility of valve materials with process media rests solely with the purchaser and end user Since some body trim material combinations are limited in their pressure drop and temp...

Page 5: ...ply pressure to the pneumatic actuator or other steps as necessary Table 3 Valve Body Data CL150 VALVE SIZE NPS SHAFT DIA AT YOKE BEARING FACE TO FACE DIMENSION 1 MINIMUM I D 2 APPROXIMATE WEIGHT KILOGRAMS Wafer and Lugged Double Flange mm Wafer Lugged Double Flange 14 30 2 92 1 191 331 2 71 7 94 8 152 16 31 75 101 6 216 375 2 93 9 137 9 201 18 38 1 114 3 222 418 8 139 3 178 3 243 20 44 45 127 0 2...

Page 6: ...pecifications 2 Minimum I D is the minimum pipe or flange I D required for disk swing clearance Applies to wafer and lugged valve bodies only CAUTION When using an actuator the actuator travel stop or actuator travel for actuators without adjustable stops must be adjusted so the disk stop in the valve does not absorb the output of the actuator Failure to limit the actuator travel as described in t...

Page 7: ... adjustment is necessary to be certain that the actuator output torque is fully absorbed by the actuator travel stop or by the actuator The internal travel stop in the valve body should not absorb any of the actuator torque 2 Before installing the valve actuator assembly in the process line cycle the valve several times to be sure the valve disk returns to the proper position Installing the Valve ...

Page 8: ...1 8 UNC 0 24 70 2 75 300 0 40 1 1 8 8 UNC 0 40 89 3 50 16 150 0 32 1 8 UNC 0 32 76 3 00 300 0 40 1 1 4 8 UNC 0 40 95 3 75 18 150 0 32 1 1 8 8 UNC 0 32 82 3 25 300 0 48 1 1 4 8 UNC 0 48 101 4 00 20 150 0 40 1 1 8 8 UNC 0 40 89 3 50 300 0 48 1 1 4 8 UNC 0 48 101 4 00 24 150 0 40 1 1 4 8 UNC 0 40 95 3 75 300 0 48 1 1 2 8 UNC 0 48 114 4 50 Double Flange Bodies Valve Size NPS Valve Rating Number of Thr...

Page 9: ...he flow properly enters the valve as indicated by the flow tag Then install the valve and the gaskets between the flanges into the cradle formed by the flange bolts 4 Install the remaining flange bolts D For Wafer Style Valves Make sure the gaskets are centered on the gasket sealing surfaces of the flange and body 5 For all Valves Tighten the flange bolts in an alternating criss cross fashion to a...

Page 10: ... leakage Excessive tightening of packing will accelerate wear and could produce higher rotating friction loads on the valve stem If necessary refer to the Packing Maintenance section 2 The ENVIRO SEAL Packing Systems will not require this initial re adjustment Refer to the separate instruction manual Fisher ENVIRO SEAL Packing System for Rotary Valves D101643X012 for repair and adjustment procedur...

Page 11: ...ews 6 For more information refer to the Packing Maintenance section below Maintenance Valve parts are subject to normal wear and must be inspected and replaced as necessary The frequency of inspection and replacement depends upon the severity of service conditions Key numbers in this procedure are shown in figures 9 and 10 unless otherwise indicated WARNING Avoid personal injury from sudden releas...

Page 12: ...tor travel can result in damage to the valve shaft s or other valve components Packing Maintenance The 8532 control valve is designed so the packing can be replaced without removing the valve from the process pipeline CAUTION For non ENVIRO SEAL packing Tighten the packing follower nuts only enough to prevent shaft leakage Excessive tightening will accelerate wear of the packing and could produce ...

Page 13: ...g bore might cause leakage 4 Before installing new packing clean the packing box 5 Install new packing one ring at a time using the packing follower as a driver If using split ring packing stagger the splits in the rings to avoid creating a leak path 6 Reinstall packing parts Refer to figures 9 and 10 for sequence of packing parts Removing the Valve 1 Disconnect any operating lines providing air p...

Page 14: ...sed by the impact of a falling or tipping of a large valve Support large valves during maintenance 2 Lay the valve flat on a work bench in a secure position with the retaining ring key 18 and retaining ring screws key 19 facing up Properly secure the valve on a suitable worktable so it cannot slip twist or fall during maintenance Remove all retaining ring screws 3 Remove the retaining ring by plac...

Page 15: ...astener materials please contact your Emerson sales office Local Business Partner PTFE Seals 1 Locate the replacement seal ring key 5 and note the shape of the ring The ring is wider across one edge diameter and narrower across the other edge diameter Around the outside circumference is one wide groove Before installing the seal ring into the valve body place the O ring key 6 into the wide outer g...

Page 16: ...after placement of the seal ring in the valve body using a blunt end screwdriver or the seal installation tool in the maintenance kit Do not use the screwdriver or seal tool directly on the metal seat Use tools on the O ring only 2 With the seal ring inserted all the way around the body T slot now lay the O ring into the opening between the valve body and the seal ring Use the seal tool to apply p...

Page 17: ...ow be done For the screw torque values refer to table 6 Anti Blowout Design Packing Valve Shaft Disk and Bearing Maintenance Note The 8532 valve has a two piece shaft In these procedures the shaft with the splined end is called the upper shaft key 3 The shaft opposite the upper shaft is called the lower follower shaft key 4 CAUTION When using an actuator the actuator travel stop or actuator travel...

Page 18: ...ance kit is available use the pin extractor to remove the disk pins Select the correct size pin extractor tip with screws of proper thread size to match the thread size in the disk pins If you do not have a kit see steps c and d below b Screw the pin extractor tip into the pin as far as possible With an upward straight sliding motion pull out the pin Repeat the same procedure for the other pins c ...

Page 19: ...a Collect the thrust bearings 10 Remove the bearings key 7 Using a suitable punch or puller drive or pull the bearings into the valve body bore from the upper shaft bearing bore Remove the bearing from the lower shaft bearing bore 11 Inspect the valve body bore bearings bearing bores and packing box for damage Note In these instructions the drive shaft with splined end is called the upper shaft ke...

Page 20: ...e upper shaft thrust bearing key 24 in the valve body bore against the counterbore of the upper shaft bearing bore Push the upper shaft through the packing box side into the bearing bore just enough to hold the thrust bearing 7 When installing the lower bearing key 4 insert one or more bearings into the lower shaft bearing bore so it is flush with the body bore 8 Insert the lower shaft through the...

Page 21: ...h the lower shaft 13 Refer to the Anti Blowout Design Packing Valve Shaft Disk and Bearing Maintenance procedures in this manual to re install the packing and anti blowout design Gasket Retainer Valves with a two piece shaft use a gasket retainer and gasket keys 20 and 21 to cover the lower shaft opening in the valve body The gasket is held in place by the gasket retainer and four hex head bolts a...

Page 22: ...ersely affect the performance of the valve and could cause personal injury and property damage Retrofit Kits Retrofit kits include all parts required for installation of the ENVIRO SEAL packing system into existing high performance butterfly valves Retrofit kits are available for single PTFE packing See table 7 for retrofit kit part numbers Retrofit Kit Included Parts Key Description Quantity 10 1...

Page 23: ...RE RATING SHAFT DIAMETER 1 2 mm Inch RETROFIT KITS REPAIR KITS PTFE PTFE 14 CL150 34 9 1 3 8 RRTYXRT0592 RRTYX000172 CL300 50 8 2 RRTYXRT0602 RRTYX000182 16 CL150 38 1 1 1 2 RRTYXRT0612 RRTYX000192 CL300 57 2 2 1 4 RRTYXRT0622 RRTYX000202 18 CL150 44 5 1 3 4 RRTYXRT0632 RRTYX000212 CL300 63 5 2 1 2 RRTYXRT0642 RRTYX000222 20 CL150 50 8 2 RRTYXRT0652 RRTYX000182 24 CL150 63 5 2 1 2 RRTYXRT0662 RRTY...

Page 24: ...ion 21 Gasket 22 Lockwasher 4 req d 23 Cap Screw 4 req d 24 Thrust Bearing 26 Retaining Ring Gasket 27 Cap Screw Actuator 4 req d not shown 28 Hex Nut Actuator 4 req d not shown 29 Nameplate not shown 32 Drive Screw 2 req d 33 Flow Direction Arrow not shown 34 Packing Box Ring 35 Disk Shaft Pin Assembly not shown ENVIRO SEAL Packing System See figure 11 10 Anti Blow Flange 17 Hex Jam Nut 4 req d 1...

Page 25: ...Instruction Manual D101550X012 8532 Valve June 2017 25 Figure 9 Fisher 8532 NPS 14 24 CL150 300 GE58725 A PARTS NOT SHOWN KEY 26 29 32 33 38 111 112 113 USE ONLY WITH SOFT SEAL AND PHOENIX III SEAL 1 1 ...

Page 26: ...anual D101550X012 8532 Valve June 2017 26 Figure 10 Fisher 8532 NPS 14 24 CL150 300 Double Flange Valve Body GE58760 A PARTS NOT SHOWN KEY 26 29 32 33 38 111 112 113 USE ONLY WITH SOFT SEAL AND PHOENIX III SEAL 1 1 ...

Page 27: ...ENVIRO SEAL Packing Systems PTFE PACKING SYSTEM 34B7524 B STACKING ORDER OF PTFE PACKING RINGS 14B0095 A 1 14B0086 A 34B7524 B GRAPHITE PACKING SYSTEM STACKING ORDER OF GRAPHITE PACKING RINGS NOTES VALVES WITH SHAFTS LARGER THAN 38 1 mm 1 1 2 INCH USE GRAPHITE RINGS ...

Page 28: ...ailable upon request We reserve the right to modify or improve the designs or specifications of such products at any time without notice E 1990 2017 Fisher Controls International LLC All rights reserved Fisher and ENVIRO SEAL are marks owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co Emerson Automation Solutions Emerson and the Emerson logo are...

Reviews: