Instruction Manual
D104483X012
785C Actuator
May 2022
28
Table 10. Tie Bolt Torque
(1)
BOLT DIAMETER
TIE ROD MATERIAL
NUT MATERIAL
TORQUE
N
w
m
lbf
w
ft
M10 x 1.5
ASTM A320-L7
ASTM A194 GR 7 S3
40
30
M12 x 1.75
70
52
M16 x 2
160
118
M20 x 2.5
320
236
M24 x 3
550
406
M27 x 3
800
590
M10 x 1.5
ASTM A320 B8M CL-2
EN ISO3506-2 A4-80
30
23
M12 x 1.75
58
43
M16 x 2
130
96
M20 x 2.5
250
185
M24 x 3
440
325
M27 x 3
535
395
1. For other bolting materials or lubricants contact your
Lubrication
The type of grease used and recommended for lubrication purposes at normal operating temperature, is described in
table 11.
Table 11. Recommended Lubricant
MANUFACTURER
AGIP
TYPE
GR MU/EP2
NLGI GRADE
2
WORKED PENETRATION (DMM)
280
DROPPING POINT ASTM (
5
C)
185
ISO GRADE
X2
EQUIVALENT GREASE
ESSO BEACON EP2
BP GREASE LTX2
SHELL ALVANIA GREASE R2
ARAL ARALUB HL2
CHEVRON DURALITH GREASE EP2
CHEVRON SPHEEROL AP2
TEXACO MULTIFAK EP2
MOBILPLEX 47
PETROMIN GREASE EP2
Check and Restore Manual Handpump Hydraulic Oil Level
During the actuator operation, the oil tank has to be closed (not in connection with the atmosphere). To avoid
cavitation, it is necessary to proceed as follows to check the oil tank oil level.
Refer to figure 45 and 46 unless otherwise indicated:
1. Remove the oil tank dipstick (key 2751-1.7).
2. Move the actuator into the open position.
3. Check that the oil level in the oil tank (key 2751-4) corresponds to the maximum level mark of the dipstick
4. With the dipstick still removed, move the actuator to the closed position using the handpump.