Table 2.

 Type 630 Regulator Outlet Pressure Ranges and Maximum Outlet Pressures

REgUlaTOR

COnSTRUCTIOn

OUTlET PRESSURE RangE

SPRIng PaRT 

nUMBER

MaXIMUM OPERaTIng 

OUTlET PRESSURE

MaXIMUM OUTlET 

PRESSURE 

OVER SETPOInT

(1)

MaXIMUM EMERgEnCy 

OUTlET (CaSIng) 

PRESSURE

(4)

psig

bar

psig

bar

psig

bar

psig

bar

low-Pressure

3 to 10

0.21 to 0.69 

0W019227022

10

0.69

20

1.38

66

4.55

8 to 20

0.55 to 1.38

0W019127022

20

1.38

17 to 30

1.17 to 2.07

0W019027022

30

2.07

20

(2)

1.38

(2)

27 to 40

1.86 to 2.76

0Y066427022

40

2.76

Limited by Maximum 

Emergency Outlet Pressure

High-Pressure

27 to 50

46 to 95

90 to 150

150 to 200

200 to 275

1.86 to 3.45

3.17 to 6.55

6.21 to 10.3

10.3 to 13.8

13.8 to 19.0

0W019227022

0W019127022

0W019027022

0Y066427022

1J146927142

50

95

150

200

275

3.45

6.55

10.3

13.8

19.0

200

13.8

550

37.9

275 to 500

19.0 to 34.5

1K370927082

500

34.5

200

(3)

1.38

(2)

1. Damage to internal parts of the regulator may occur if outlet pressure exceeds the actual pressure setting by amounts greater than those shown in this column.

2. For outlet pressure settings to 25 psig / 1.72 bar only. For pressure settings over 25 psig / 1.72 bar, outlet pressure is limited by maximum emergency outlet pressure of 45 psig / 3.10 bar.

3. For outlet pressure settings to 350 psig / 24.1 bar only. For pressure settings over 350 psig / 24.1 bar, outlet pressure is limited by maximum emergency outlet pressure of 550 psig / 37.9 bar.

4. Leakage or bursting of pressure-containing parts may occur if outlet pressure exceeds these values.

Table 3.

 Type 630R Relief Pressure Ranges

RElIEf ValVE

COnSTRUCTIOn

RElIEf (InlET) 

PRESSURE RangE

PaRT nUMBER

MaXIMUM allOWaBlE 

RElIEf (InlET) PRESSURE, 

psig / bar

MaXIMUM EMERgEnCy 

InlET (CaSIng) PRESSURE

(1)

psig

bar

psig

bar

low-Pressure

3 to 8

6 to 17

15 to 22

20 to 35

35 to 50

0.21 to 0.55

0.41 to 1.17

1.03 to 1.52

1.38 to 2.41

2.41 to 3.45

0W019227022

0W019127022

0W019027022

0Y066427022

1J146927142

Relief Pressure Setting Plus 

Maximum Allowable Buildup of 

25 psig / 1.72 bar

75

5.17

High-Pressure

30 to 70

50 to 95

75 to 175

150 to 250

2.07 to 4.83

3.45 to 6.55

5.17 to 12.1

10.3 to 17.2

0W019127022

0W019027022

0Y066427022

1J146927142

Relief Pressure Setting Plus 

Maximum Allowable Buildup of 

250 psig / 17.2 bar

550

37.9

1. Leakage or bursting of pressure-containing parts may occur if inlet pressure exceeds these values.

To avoid overpressure, provide an 

appropriate overpressure protection 

device to ensure that none of the limits 

listed in Specifications section, Tables 1 

through 3 will be exceeded.

Regulator or relief valve operation below the limits 

specified in Specifications section, Tables 1 through 3 

does not preclude the possibility of damage from external 

sources or from debris in the gas line. Inspect the 

regulator for damage after any overpressure condition.

Startup

Starting up the unit consists of opening the upstream 

block valve, introducing gas pressure. Use gauges to 

monitor pressures during startup.
The range of allowable pressure settings is marked 

on the nameplate. If a pressure setting beyond the 

nameplate range is required, substitute an appropriate 

spring selected from Table 5. Be sure to change the 

nameplate to indicate the new pressure range.

Table 1. 

Maximum Allowable Inlet Pressures and Pressure Drops

ORIfICE SIzE

MaXIMUM allOWaBlE 

InlET PRESSURE

(1)

MaXIMUM allOWaBlE PRESSURE DROP

nylon (Pa)

(2)

 and

Polytetrafluoroethylene 

(PTfE) Disk

fluorocarbon (fKM) Disk

nitrile (nBR)

(2)

 Disk

In.

mm

psig

bar

psig

bar

psig

bar

psig

bar

1/8 and 3/16 

3.2 and 4.8

1500

103

1500

103

200

13.8

600

 41.4

1/4

6.4

1000

69

3/8

9.5

1000

69

500

34.5

500

34.5

1/2

13

750

51.7

250

17.2

250

17.2

Note: Maximum inlet pressure not exceeded 1500 psig / 103 bar.

1.  Inlet pressure must not exceed the sum of the actual outlet pressure setting and the maximum allowable pressure drop. For example, with an outlet pressure setting of 200 psig / 13.8 bar 

and a 3/8 in. / 9.5 mm orifice with a maximum allowable pressure drop of 500 psid / 34.5 bar d, the maximum inlet pressure is 700 psig / 48.3 bar.

2.  Nitrile (NBR) valve disks are normally furnished for pressure drops to 200 psi / 13.8 bar, differential. For better erosion resistance, Nylon (PA) valve disks are normally furnished for 

higher 

pressure drops. Some erosion of valve disks occurs at all pressure drops due to solid particles in the flow stream. The rate of erosion is higher with large amounts of impurities in the 

flow stream and with high pressure drops. Valve disks and other regulator parts must be inspected periodically for erosion and damage and must be replaced as necessary. 

Summary of Contents for Fisher 630 Series

Page 1: ...or is installed where service conditions could exceed the limits given in Specifications section Tables 1 through 3 or where conditions exceed any ratings of the adjacent piping or piping connections To avoid such injury or damage provide pressure relieving or pressure limiting devices as required by the appropriate code regulation or standard to prevent service conditions from exceeding those lim...

Page 2: ...caping gas may accumulate and be an explosion hazard Under these conditions the vent should be piped away from the unit to a freely ventilated outdoor location away from air intakes windows etc Protect all vent openings against weather or the entrance of any foreign material that may plug the vent or affect operation of the regulator or relief valve Inspect all vent openings periodically to be sur...

Page 3: ...Setting Plus Maximum Allowable Buildup of 250 psig 17 2 bar 550 37 9 1 Leakage or bursting of pressure containing parts may occur if inlet pressure exceeds these values To avoid overpressure provide an appropriate overpressure protection device to ensure that none of the limits listed in Specifications section Tables 1 through 3 will be exceeded Regulator or relief valve operation below the limits...

Page 4: ...king adjustments Adjusting Spring Loaded Regulators and Relief Valves Loosen the hex nut key 2 Figures 4 5 and 6 atop the spring case While monitoring the pressure rotate the adjusting screw key 1 Figures 4 5 and 6 clockwise to increase set pressure or counterclockwise to decrease it When the unit is regulating or relieving pressure at the desired value tighten the hex nut Shutdown Slowly close th...

Page 5: ...ice key 20 and the Type 630R valve seat O ring key 37 Figure 6 caution If step 1 is omitted and the body and inlet adaptor are separated take care to avoid pinching fingers between the body and the inlet adaptor 1 Disconnect piping from inlet adaptor key 18 Remove four cap screws key 17 and adaptor 2 Remove orifice key 20 and gaskets key 19 3 To remove Type 630 valve disk key 21 Figures 4 and 5 or...

Page 6: ...screwing cap screws and nuts keys 9 10 and 30 4 Remove diaphragm key 11 and attached parts from the lever key 14 5 Unscrew cap screw key 6 from connector head assembly key 12 and disassemble the diaphragm assembly 6 Install new diaphragm being certain that the diaphragm is centered Note that low pressure constructions use a diaphragm plate key 8 Figure 5 on the spring case side of the diaphragm In...

Page 7: ...in the following parts list Separate kit containing all recommended spare parts is available Parts List Note In this parts list parts marked NACE are intended for corrosion resistant service as detailed in the NACE International Standard MR0175 Parts Kits Type 630 regulator kits are for low or high pressure spring loaded construction Kits include neoprene diaphragm copper inlet gasket material for...

Page 8: ...0X000H52 Stainless steel PTFE R630X000H62 Key Description Part Number High Pressure continued With orifice key 20 1 8 in 3 18 mm Brass Nylon PA R630X000HC2 1 8 in 3 18 mm Stainless steel Nylon PA standard R630X000HD2 1 8 in 3 18 mm Stainless steel Nylon PA NACE R630X00NHD2 1 4 in 6 35 mm Brass Nylon PA R630X000HA2 1 4 in 6 35 mm Stainless steel Nylon PA standard R630X000HB2 1 4 in 6 35 mm Stainles...

Page 9: ...6985X0072 High pressure Cast iron 0W019819012 Steel 2N698722012 Steel NACE 2N6987X0042 14 Lever Assembly Steel or Stainless steel Low pressure 1B2891000A2 Low pressure NACE 1B2891X0032 High pressure 1B2890000A2 High pressure NACE 1B2890X0022 Key Description Part Number 15 Pin Stainless steel 0W018835172 Stainless steel NACE 0W0188X0022 16 Gasket Composition 0W018704022 17 Cap Screw steel 4 require...

Page 10: ...1 NPT 0W0209000A2 2 NPT 0W021519012 Steel 1 NPT 2N6990000A2 1 NPT NACE 2N6990X0092 2 NPT 2N699122012 2 NPT NACE 2N6991X0032 CL150 RF 1 in DN 25 27B3333X012 2 in DN 50 27B3336X012 2 in DN 50 Type 630R only 28B6244X012 CL300 RF 1 in DN 25 27B3334X012 2 in DN 50 27B3337X012 2 in DN 50 Type 630R only 28B6245X012 CL600 RF 1 in DN 25 27B3335X012 2 in DN 50 27B3338X012 2 in DN 50 Type 630R only 28B6246X0...

Page 11: ...or Code psig bar Spring Loaded Type 630 Low Pressure 3 to 10 8 to 20 17 to 30 27 to 40 0 21 to 0 69 0 55 to 1 38 1 17 to 2 07 1 86 to 2 76 0W019227022 0W019127022 0W019027022 0Y066427022 Red Stripe Olive Drab Silver Green Stripe High Pressure 27 to 50 46 to 95 90 to 150 150 to 200 200 to 275 275 to 500 1 86 to 3 45 3 17 to 6 55 6 21 to 10 3 10 3 to 13 8 13 8 to 19 0 19 0 to 34 5 0W019227022 0W0191...

Page 12: ...intenance of any Emerson Process Management Regulator Technologies Inc product remains solely with the purchaser Industrial Regulators Emerson Process Management Regulator Technologies Inc USA Headquarters McKinney Texas 75070 USA Tel 1 800 558 5853 Outside U S 1 972 548 3574 Asia Pacific Shanghai 201206 China Tel 86 21 2892 9000 Europe Bologna 40013 Italy Tel 39 051 419 0611 Middle East and Afric...

Reviews: